High Power Electronic Load 63200A Series Operation & Programming Manual
RESistance:STATic:RISE
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = A/μs]
Query Example:
RESistance:STATic:FALL
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = A/μs]
Query Example:
RESistance:STATic:IRNG
Type:
Description:
Setting Syntax:
Setting Parameters:<CRD | NR1>, LOW | L | 0, MIDDLE | M | 1, HIGH | H | 2
Setting Example:
Query Syntax:
Return Parameters:<CRD>, LOW(0), MIDDLE(1), HIGH(2)
Query Example:
RESistance:DYNamic:L1
Type:
Description:
4-20
RES:STAT:L2? MIN
Channel-Specific
Set the rising slew rate of current for constant resistance mode.
RESistance:STATic:RISE<space><NRf+>[suffix]
RES:STAT:RISE 2.5
RES:STAT:RISE 1A/μs
RES:STAT:RISE MAX
RES:STAT:RISE MIN
RESistance:STATic:RISE?[<space><MAX | MIN>]
RES:STAT:RISE?
RES:STAT:RISE? MAX
RES:STAT:RISE? MIN
Channel-Specific
Set the falling slew rate of current for constant resistance mode.
RESistance:STATic:FALL<space><NRf+>[suffix]
RES:STAT:FALL 2.5
RES:STAT:FALL 1A/μs
RES:STAT:FALL MAX
RES:STAT:FALL MIN
RESistance:STATic:FALL?[<space><MAX | MIN>]
RES:STAT:FALL?
RES:STAT:FALL? MAX
RES:STAT:FALL? MIN
Channel-Specific
Set the current measurement range in CR mode.
RESistance:STATic:IRNG<space><CRD | NR1>
RES:STAT:IRNG HIGH
RES:STAT:IRNG M
RES:STAT:IRNG 0
RESistance:STATic:IRNG?
RES:STAT:IRNG?
Channel-Specific
Set the load resistance during T1 period for constant resistance
dynamic mode.
Set rising slew rate to 2.5A/μs.
Set rising slew rate to 1A/μs.
Set rising slew rate to the
maximum value of static load.
Set rising slew rate to the
minimum value of static load.
Set falling slew rate to 2.5A/μs.
Set falling slew rate to 1A/μs.
Set falling slew rate to the
maximum value of static load.
Set falling slew rate to the
minimum value of static load.
Set current range to High.
Set current range to Middle.
Set current range to Low.
[Unit = None]