Chroma 63200A Series Operation & Programming Manual page 74

High power dc electronic loads
Table of Contents

Advertisement

CONFigure:VOLTage:LATCh
Type:
Description:
Setting Syntax:
Setting Parameters:<CRD | NR1>, OFF(0),ON(1)
Setting Example:
Query Syntax:
Return Parameters:<CRD>, OFF(0), ON(1)
Query Example:
CONFigure:VOLTage:LATCh:RESet
Type:
Description:
Setting Syntax:
Setting Parameters:None.
Setting Example:
CONFigure:VOLTage:SIGN
Type:
Description:
Setting Syntax:
Setting Parameters:<CRD | NR1>, PLUS(0), MINUS(1)
Setting Example:
Query Syntax:
Return Parameters:<CRD>, PLUS(0), MINUS(1) [Unit = None]
Query Example:
CONFigure:WINDow
Type:
Description:
Setting Syntax:
Setting Parameters:<NRf+>, 0.02s ~ 61.00s, Resolution = 20ms, Unit = Second
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Second]
Query Example:
CONFigure:SYNChronous:MODE
Type:
Description:
Setting Syntax:
Setting Parameters:<CRD | NR1>, NONE(0), MASTER(1), SLAVE(2)
Setting Example:
Query Syntax:
Return Parameters:<CRD>, NONE(0), MASTER(1), SLAVE(2)
Channel-Specific
Set the action type of Von.
CONFigure:VOLTage:LATCh<space><CRD | NR1>
CONF:VOLT:LATC OFF
CONF:VOLT:LATC 1
CONFigure:VOLTage:LATCh?
CONF:VOLT:LATC?
Channel-Specific
Resets the Von signal.
CONFigure:VOLTage:LATCh:RESet
CONF:VOLT:LATC:RES
Channel-Specific
Set the sign of voltage measurement to Plus/Minus.
CONFigure:VOLTage:SIGN<space><CRD | NR1>
CONF:VOLT:SIGN PLUS
CONF:VOLT:SIGN 1
CONFigure:VOLTage:SIGN?
CONF:VOLT:SIGN?
Channel-Specific
Set the time of measure over which the window calculation is to be
performed.
CONFigure:WINDow<space><NRf+>
CONF:WIND 0.5
CONF:WIND MAX
CONF:WIND MIN
CONFigure:WINDow?[<space><MAX | MIN>]
CONF:WIND?
CONF:WIND? MAX
CONF:WIND? MIN
Channel-Specific
Set the synchronization mode.
CONFigure:SYNChronous:MODE<space><CRD | NR1>
CONF:SYNC:MODE MASTER
CONF:SYNC:MODE 0
CONFigure:SYNChronous:MODE?
Set Von latch function to OFF.
Set Von latch function to ON.
[Unit = None]
Resets the Von Signal.
Set sign of voltage to Plus.
Set sign of voltage to Minus.
Set times of window = 0.5s
Set times of window = maximum value.
Set times of window = minimum value.
Set sync. mode to MASTER.
Set sync. mode to NONE.
Remote Operation
[Unit = None]
4-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

63200a-150-60063200a-150-400

Table of Contents