High Power Electronic Load 63200A Series Operation & Programming Manual
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Second]
Query Example:
[ADVance:]CURRent:SWEep:DUTY
Type:
Description:
Setting Syntax:
Setting Parameters:<NRf+>, 1% ~ 99%, Resolution = 1%
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = None]
Query Example:
[ADVance:]CURRent:SWEep:RISE
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = A/μs]
Query Example:
[ADVance:]CURRent:SWEep:FALL
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
4-36
CURR:SWE:DWEL 50
CURR:SWE:DWEL 500ms
CURR:SWE:DWEL MAX
CURR:SWE:DWEL MIN
[ADVance:]CURRent:SWEep:DWELl?[<space><MAX | MIN>]
CURR:SWE:DWEL?
CURR:SWE:DWEL? MAX
CURR:SWE:DWEL? MIN
Channel-Specific
Set the duty cycle for constant current frequency sweep mode.
[ADVance:]CURRent:SWEep:DUTY<space><NRf+>
CURR:SWE:DUTY 50
CURR:SWE:DUTY MAX
CURR:SWE:DUTY MIN
[ADVance:]CURRent:SWEep:DUTY?[<space><MAX | MIN>]
CURR:SWE:DUTY?
CURR:SWE:DUTY? MAX
CURR:SWE:DUTY? MIN
Channel-Specific
Set the rising slew rate of current for constant current frequency
sweep mode.
[ADVance:]CURRent:SWEep:RISE<space><NRf+>[suffix]
CURR:SWE:RISE 2.5
CURR:SWE:RISE 1A/μs
CURR:SWE:RISE MAX
CURR:SWE:RISE MIN
[ADVance:]CURRent:SWEep:RISE?[<space><MAX | MIN>]
CURR:SWE:RISE?
CURR:SWE:RISE? MAX
CURR:SWE:RISE? MIN
Channel-Specific
Set the falling slew rate of current for constant current frequency
sweep mode.
[ADVance:]CURRent:SWEep:FALL<space><NRf+>[suffix]
CURR:SWE:FALL 2.5
CURR:SWE:FALL 1A/μs
CURR:SWE:FALL MAX
CURR:SWE:FALL MIN
Set dwell time = 50s
Set dwell time = 0.5s
Set dwell time = maximum value.
Set dwell time = minimum value.
Set duty cycle = 50%
Set duty cycle = maximum value.
Set duty cycle = minimum value.
Set rising slew rate to 2.5A/μs.
Set rising slew rate to 1A/μs.
Set rising slew rate to the maximum
value of static load.
Set rising slew rate to the minimum
value of static load.
Set falling slew rate to 2.5A/μs.
Set falling slew rate to 1A/μs.
Set falling slew rate to the
maximum value of static load.
Set falling slew rate to the