Performance Tests; Cc Mode Verification - Chroma 63200A Series Operation & Programming Manual

High power dc electronic loads
Table of Contents

Advertisement

High Power Electronic Load 63200A Series Operation & Programming Manual
6.3

Performance Tests

6.3.1

CC Mode Verification

This test verifies if the current programming and readings are within specifications when
operating in CC mode. For each DMM reading, the front panel display of current should be
identical.
The reading of the Load in amps = Shunt current  inaccuracy.
DMM (V): means DMM dc voltage of voltage measurement
DMM (I): means DMM dc voltage of current shunt measurement
DMM (DC): means DMM in dc voltage measurement
Shunt current (DMM Ai): means DMM (I) voltage/shunt resistor
Checking High Current Range
A.
Connect the Load, DC Source, DMM and Current Shunt as shown in Figure 6-1. Use
DMM (I) to measure the voltage that passes through the shunt resistor measurement
port, and get the load current.
B.
Select the right range for the current shunt resistor. Press
RANGE
press
to H range.
EDIT
C.
Press
to enter into CC Mode for setting. Use push button rotary and
to program the current listed in Table 6-2.
D.
Turn on the DC source and set output voltage to 5V. Set current limit of DC source
larger than the set current in Table 6-2. Press
30 seconds. Then record the shunt current and the front panel displayed readings. The
current of load can be recorded from current shunt = DMM (I) voltage/current shunt
resistor.
Model
63205A-150-500
63206A-150-600
Checking Medium Current Range
A.
After tested the high current range, press
EDIT
B.
Press
to enter into CC Mode for setting. Use push button rotary and
to program the current listed in Table 6-3.
C.
Turn on the DC source and set output voltage to 5V. Set current limit of DC source
larger than the set current in Table 6-3. Press
30 seconds. Then record the shunt current and the front panel displayed readings. The
current of load can be recorded from current shunt = DMM (I) voltage/current shunt
6-2
Table 6-2
CCH Current
Setting
Max.
500.0 A
5.0A
600.0 A
6.0A
LOAD
to enable the load and wait for
Shunt Current
Min.
500.45A
499.55A DMM Ai ±0.45A
5.25A
4.75A DMM Ai ±0.25A
600.48A
599.52A DMM Ai ±0.48A
6.24A
5.76A DMM Ai ±0.24A
RANGE
to M range.
LOAD
to enable the load and wait for
MODE
to select CC and
Front Panel Display
Reading
or
or

Advertisement

Table of Contents
loading

This manual is also suitable for:

63200a-150-60063200a-150-400

Table of Contents