High Power Electronic Load 63200A Series Operation & Programming Manual
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Ampere]
Query Example:
SPECification:CURRent:L
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Ampere]
Query Example:
SPECification:POWer:C
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Watt]
Query Example:
SPECification:POWer:H
Type:
Description:
Setting Syntax:
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
Query Syntax:
Return Parameters:<NR2>, [Unit = Watt]
Query Example:
SPECification:POWer:L
Type:
Description:
4-48
Set the high-level current specification. The -1 mean don't care.
SPECification:CURRent:H<space><NRf+>[suffix]
SPEC:CURR:H 10
SPEC:CURR:H 10mA
SPECification:CURRent:H?[<space><MAX | MIN>]
SPEC:CURR:H?
SPEC:CURR:H? MAX
SPEC:CURR:H? MIN
Channel-Specific
Set the low-level current specification. The -1 mean don't care.
SPECification:CURRent:L<space><NRf+>[suffix]
SPEC:CURR:L 10
SPEC:CURR:L 10mA
SPECification:CURRent:H?[<space><MAX | MIN>]
SPEC:CURR:L?
SPEC:CURR:L? MAX
SPEC:CURR:L? MIN
Channel-Specific
Set the center-level power specification. The -1 mean don't care.
SPECification:POWer:C<space><NRf+>[suffix]
SPEC:POW:C 10
SPEC:POW:C 10mW
SPECification:POWer:C?[<space><MAX | MIN>]
SPEC:POW:C?
SPEC:POW:C? MAX
SPEC:POW:C? MIN
Channel-Specific
Set the high-level power specification. The -1 mean don't care.
SPECification:POWer:H<space><NRf+>[suffix]
SPEC:POW:H 10
SPEC:CURR:H 10mW
SPECification:POWer:H?[<space><MAX | MIN>]
SPEC:POW:H?
SPEC:POW:H? MAX
SPEC:POW:H? MIN
Channel-Specific
Set the low-level power specification. The -1 mean don't care.