High Power Electronic Load 63200A Series Operation & Programming Manual
Query Example:
Return Example:
FETCh:VOLTage:MIN?
Type:
Description:
Query Syntax:
Return Parameters:<NR2>, [Unit = Voltage]
Query Example:
Return Example:
FETCh:VOLTage:PEAK+?
Type:
Description:
Query Syntax:
Return Parameters:<NR2>, [Unit = Voltage]
Query Example:
Return Example:
FETCh:VOLTage:PEAK+:FREQuency?
Type:
Description:
Query Syntax:
Return Parameters:<NR2>, [Unit = Hertz]
Query Example:
Return Example:
FETCh:VOLTage:PEAK-?
Type:
Description:
Query Syntax:
Return Parameters:<NR2>, [Unit = Voltage]
Query Example:
Return Example:
FETCh:VOLTage:PEAK-:FREQuency?
Type:
Description:
Query Syntax:
Return Parameters:<NR2>, [Unit = Hertz]
Query Example:
Return Example:
FETCh:ALLVoltage:MAX?
Type:
Description:
Query Syntax:
4-52
FETC:VOLT:MAX?
8.12
Channel-Specific
Returns the minimum voltage measured at electronic load input in
CZ mode.
FETCh:VOLTage:MIN?
FETC:VOLT:MIN?
8.12
Channel-Specific
Returns the peak+ voltage measured at electronic load input in
CCD, CCFS and sine wave dynamic mode.
FETCh:VOLTage:PEAK+?
FETC:VOLT:PEAK+?
8.12
Channel-Specific
Returns the frequency at peak+ voltage measured in frequency
sweep mode.
FETCh:VOLTage:PEAK+:FREQuency?
FETC:VOLT:PEAK+:FREQ?
8.12
Channel-Specific
Returns the peak- voltage measured at electronic load input in CCD,
CCFS and sine wave dynamic mode.
FETCh:VOLTage:PEAK-?
FETC:VOLT:PEAK-?
8.12
Channel-Specific
Returns the frequency at peak- voltage measured in frequency
sweep mode.
FETCh:VOLTage:PEAK-:FREQuency?
FETC:VOLT:PEAK-:FREQ?
8.12
Channel-Independent
Returns the maximum voltage measured at the input of all load
modules. The return value is 0 when the channel does not exist.
FETCh:ALLVoltage:MAX?