Alcatel-Lucent 1665 Installation Manual page 275

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

WDMX setup and testing: integration procedures
........................................................................................................................................................................
................................................................................................................................................
4
Login to the Alcatel-Lucent 1665 DMXtend using the WaveStar
................................................................................................................................................
5
Provision the PTM/OTU-2
Select Configuration > Equipment from the System View
................................................................................................................................................
6
Click the "+" next to XM10G/8 circuit pack to expand the list.
................................................................................................................................................
7
Highlight the PTM sc9 and click Select.
................................................................................................................................................
8
Enter the Frequency in the Expected Frequency and click Apply.
Note:
column in
................................................................................................................................................
9
Highlight the Port 1 and click Select.
................................................................................................................................................
10
Set the Signal type to match the PTM type, using the pull down window (for example if
the PTM is a OC48SR1-I1
................................................................................................................................................
11
Perform a single node self test by connecting an OC-48 test set to Port 1, while observing
the proper optical power levels and cleaning procedures.
Insert a 15 dB LBO into the input of Port 9 and connect a fiber from the output of Port 9 to
the input of Port 9.
................................................................................................................................................
12
Connect an OC-48 test set to the PTM in port 1 while observing the proper optical power
levels listed in
................................................................................................................................................
13
Condition the test set to transmit and receive a STS-48 PRBS test signal.
Result:
........................................................................................................................................................................
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013
The frequency is determined by the PTM inserted in Port 9. See the LNW705
Table 8-3, "Channel/port assignments" (p. 8-19)
, set the Signal Type to OC48) and click
Table 8-4, "Attenuation Table" (p.
Observe error-Free Transmission.
®
CIT.
for acceptable values.
Apply
.
8-19).
8 - 7