Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
1
Beginning from the top (G) of the Alcatel-Lucent 1665 DMXtend shelf, locate the first
function unit slot that contains an OC-12 OLIU circuit pack.
........................................................................................................................................................................................................................
2
Insert a 15-dB LC-type LBO into the top IN connector (port 1) of the OC-12 OLIU. See
Appendix C, "Installing fiber connectors and
Connect the fibers labeled IN and OUT from the LGX to the OLIU (port 1).
........................................................................................................................................................................................................................
3
Connect the Port 1 IN connector to the Port 1 OUT connector (at the LGX) of the OC-12
OLIU, using an optical fiber jumper cable. See
fiber cleaning instructions.
Result:
NE LEDs should be lit on the SYSCTL circuit pack.
After approximately 20 seconds the flashing FAULT LED should extinguish on the
OC-12 OLIU and the FAULT, MJ and NE LEDs should be lit on the SYSCTL circuit
pack.
........................................................................................................................................................................................................................
4
Remove the optical fiber jumper from the OC-12 OLIU (at the LGX).
Result:
and NE LEDs should be lit on the SYSCTL circuit pack.
........................................................................................................................................................................................................................
5
If not still connected from the previous procedure. Connect the Front CIT cable between
the PC and the CIT/RS 232 port or OSI front LAN port of the System Controller and login
to the shelf using the serial/LAN connection and the GUI options on WaveStar
........................................................................................................................................................................................................................
6
Use the
........................................................................................................................................................................................................................
7
Click on the
Result:
There should be no alarm indications on the Alcatel-Lucent 1665 DMXtend shelf.
............................................................................................................................................................................................................................................................
6 - 3 0
The FAULT LED on the OC-12 OLIU will begin flashing and the MN and IN
The FAULT LED should begin flashing on the OC-12 OLIU and only the MN
GUI
window to send the
Configuration > Update System > Update All.
The flashing FAULT LED should extinguish on the OC-12 OLIU.
LBOs".
Appendix A, "Fiber cleaning"
upd-sys
command.
for proper
®
CIT.
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013