Stand-alone installation testing
............................................................................................................................................................................................................................................................
Tools, test equipment and accessories
Listed below are the required tools, test equipment and accessories. For complete listing,
see Part I or Part II:
Quantity
1
1
1
2 or 3
1
1
1
2
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013
Description
Comments
Screwdriver(s)
A screwdriver(s) with the appropriate head(s) is (are)
required for securing the mounting screws,
repositioning the mounting brackets, installing the
interfacing cables, and for setting the circuit breakers to
the OFF position.
ESD Wrist Strap
A wrist strap must be worn when handling circuit packs.
Use the electrostatic discharge (ESD) jack provided on
the shelf.
DS1/E1 Error Rate
A DS1/E1 error rate test set is required for testing of
Test Set
DS1/E1 cabling. A T-BERD 2209 or equivalent is
recommended.
DS3 Error Rate
A DS3 error rate test set is required for testing of
Test Set
DS3/EC1 cabling. A T-BERD 2209 or equivalent is
recommended.
LC-type Optical
Two optical fiber jumpers with LC-type connectors are
Fiber Jumper
required to optically loop the Alcatel-Lucent 1665
(108918269)
DMXtend shelf for test purposes. In addition, for
shelves containing optical circuit packs in any of the
function unit slots, a single optical fiber jumper is
required for testing of the individual ports.
15 dB LC-type
For shelves containing optical circuit packs in any of the
LBO (108279480)
function unit slots (supported starting in release R1.1), a
single 15-dB LBO is required for testing of the
individual ports
Personal Computer
Required to run the WaveStar
(PC)
CIT (RS-232)
8-ft. long RJ45 to 9-pin D-sub serial cable (Comcode
Interface Cable
848748869). Required to connect the PC to the CIT jack
on the front of the SYSCTL circuit pack.
LAN 10BaseT
As required to reach from front of Alcatel-Lucent 1665
Straight-through
DMXtend to the RJ45 patch panel
Cable CAT 5 or
better
®
CIT software.
6 - 3