Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
10
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
OC-192 facility loopback testing
Facility Loopback testing allows the installer to verify cabling to the OC-192 equipment.
This test is only required if the Alcatel-Lucent 1665 DMXtend shelf is connected to OC-
192 equipment. If the shelf is NOT connected to OC-192 equipment, skip this section and
continue to the next chapter.
Note:
necessary for the testing.
The Function unit slot under test must contain an OC-192 (LNW603) circuit pack in order
to perform this test.
........................................................................................................................................................................................................................
1
Log on to the Alcatel-Lucent 1665 DMXtend shelf using the CIT software.
........................................................................................................................................................................................................................
2
Select Configuration > Cross-Connections...
........................................................................................................................................................................................................................
3
Use the Cross-Connection Wizard to enter a new cross-connection at the STS192 rate,
UPSR Ring Add/Drop, between m1-1-1 and fn-1-1 (fn is either d or g depending on the
slot where the OC-192 CP is located).
This command creates a cross-connect to map the first STS-192 of an OC-192 circuit pack
to the first STS-192 of the Main OLIUs.
........................................................................................................................................................................................................................
4
Verify transmission at the patch panel. There should be no alarms at the test set.
........................................................................................................................................................................................................................
5
Select Configuration > Cross-Connections...
........................................................................................................................................................................................................................
6
Use the Cross-Connection Wizard to Delete leg(s) of an existing cross-connection
associated with CP main-1, Port 1 (the OC-192 cross-connection).
............................................................................................................................................................................................................................................................
6 - 3 8
S
F
T E P S
An optical test set with the capability to transmit OC-192 SONET levels are
"Installation checklist" (p.
II-5).
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013