Alcatel-Lucent 1665 Installation Manual page 223

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
7
Verify loss of transmission at the patch panel. This should be evident by a SONET alarm
and a loss of pattern alarm.
........................................................................................................................................................................................................................
8
Select Fault > Analysis > Loopback...
........................................................................................................................................................................................................................
9
Choose the correct port on the OC-192 CP and click Select.
........................................................................................................................................................................................................................
10
Click on Operate and Loopback Type: Facility.
........................................................................................................................................................................................................................
11
Click Apply.
This command creates a facility loopback on the OC-192 port of an OC-192 circuit pack.
........................................................................................................................................................................................................................
12
Verify transmission at the patch panel. There should be no alarms at the test set.
........................................................................................................................................................................................................................
13
Select Fault > Analysis > Loopback...
........................................................................................................................................................................................................................
14
Choose the correct port on the OC-192 CP and click Select.
........................................................................................................................................................................................................................
15
Click on Release.
........................................................................................................................................................................................................................
16
Click Apply.
........................................................................................................................................................................................................................
17
Verify loss of transmission at the patch panel. This should be evident by a SONET alarm
and a loss of pattern alarm.
........................................................................................................................................................................................................................
18
Repeat this section for all OC-192 ports.
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013
6 - 3 9