Alcatel-Lucent 1665 Installation Manual page 175

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Stand-alone node setup
........................................................................................................................................................................
Connect IN to OUT on the OLIU in the M2 slot of the Alcatel-Lucent 1665 DMXtend
shelf using an optical fiber jumper cable and a 15-dB LBO.
Result:
OLIU circuit pack. If the shelf is externally timed the flashing FAULT LEDs may not
extinguish until correct framing is selected. The FAULT, MJ and NE LEDs will light
on the SYSCTL due to DCC alarms created by optically looping the OLIUs. These
SYSCTL LEDs will remain lit until the DCC is disabled in the
(p. 6-7)
................................................................................................................................................
5
Starting with slot A1/B1, fully seat the circuit pack slotted there using a steady pressure on
both of the faceplate latches (where applicable) at the same time until the circuit pack is
fully seated.
Note:
and the FAULT LED should extinguish after a short period of time.
Note:
of the circuit pack, slide the circuit pack into the slot until it is fully seated. Then close
the faceplate latch.
................................................................................................................................................
6
Continue seating circuit packs with slot A2/B2 and then on to G1, G2, D1, and D2.
Note:
minutes before their FAULT LEDs extinguish.
................................................................................................................................................
7
Fully seat 177D or LNW98 Apparatus Blanks in any other unfilled D and G slots.
................................................................................................................................................
8
Fully seat LNW43 or LNW96 Apparatus Blanks in any A/B unfilled slots.
Note:
circuit pack into the slot until it is fully seated. Then close the faceplate latch.
........................................................................................................................................................................
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013
CAUTION
Equipment damage
The LNW38, LNW40, LNW51, LNW302, LNW382, and LNW601 OLIU circuit
packs are equipped with optics that do not meet GR-78 R9-3 requirements on
ESD susceptibility. Always use proper ESD procedures when handling these
OLIU circuit packs to avoid equipment damage.
After a few minutes the flashing FAULT LEDs should extinguish on each
section.
The ACTIVE and FAULT LEDs should light when circuit packs are inserted
For slots A1/B1 and A2/B2 only; using a gentle steady pressure on both ends
Some circuit packs such as the LNW63 and LNW170 may take several
Using a gentle steady pressure on both ends of the circuit pack, slide the
"Clearing alarms"
5 - 5