Alcatel-Lucent 1665 Installation Manual page 212

Data multiplexer extend (dmxtend)
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
Result:
LEDs should be lit on the SYSCTL circuit pack.
After approximately 20 seconds the flashing FAULT LED should extinguish on the
OC-3 OLIU and the FAULT, MJ and NE LEDs should be lit on the SYSCTL circuit
pack.
........................................................................................................................................................................................................................
4
Remove the optical fiber jumper from the OC-3 OLIU (at the LGX).
Result:
and NE LEDs should be lit on the SYSCTL circuit pack.
........................................................................................................................................................................................................................
5
If not still connected from the previous procedure. Connect the Front CIT cable between
the PC and the CIT/RS 232 port or OSI front LAN port of the System Controller and login
to the shelf using the serial/LAN connection and the GUI options on WaveStar
........................................................................................................................................................................................................................
6
Use the GUI window to send the
........................................................................................................................................................................................................................
7
Click on the
Result:
There should be no alarm indications on the Alcatel-Lucent 1665 DMXtend shelf.
........................................................................................................................................................................................................................
8
Remove PTM if necessary and the 15-dB LBO from OC-3 OLIU from (port 1) and plug it
into the IN connector directly below it (port 2).
........................................................................................................................................................................................................................
9
Connect the fibers labeled IN and OUT from the LGX to the OLIU (port 2).
........................................................................................................................................................................................................................
10
Connect the Port 2 IN connector to the Port 2 OUT connector (at the LGX) of the OC-3
OLIU, using an optical fiber jumper cable.
Result:
LEDs should be lit on the SYSCTL circuit pack.
After approximately 20 seconds the flashing FAULT LED should extinguish on the
OC-3 OLIU and the FAULT, MJ and NE LEDs should be lit on the SYSCTL circuit
pack.
............................................................................................................................................................................................................................................................
6 - 2 8
The FAULT LED on the OC-3 OLIU will begin flashing and the MN and NE
The FAULT LED should begin flashing on the OC-3 OLIU and only the MN
upd-sys
Configuration > Update System > Update All
The flashing FAULT LED should extinguish on the OC-3 OLIU.
The FAULT LED on the OC-3 OLIU will begin flashing and the MN and NE
command.
Alcatel-Lucent 1665 DMXtend R10.0
®
CIT.
365-372-327R10.0 Issue 1