Connecting adjacent network elements
........................................................................................................................................................................
................................................................................................................................................
8
Set NE window
In the
................................................................................................................................................
9
Dress optical cables out of the shelf to the left side of the shelf.
Note:
allow the circuit packs in slots A1/B1 and A2/B2 to be inserted or removed.
................................................................................................................................................
10
Route the optical jumpers from the left side of the shelf.
................................................................................................................................................
11
Establish communications with the technician at the other end of the optical span.
................................................................................................................................................
12
At both ends of the optical span, remove protective covers from receive and transmit
optical jumper cables and clean LC connectors.
Note:
cable. Single-mode optical fibers connecting this shelf with the far-end shelf should
not be connected to the OLIU until at least 45 seconds after an optical loopback is
removed. It may take from 15 seconds to 3.5 minutes for the FAULT LEDs to stop
flashing after the cables are connected, depending on the setting of the OC-3/OC-
12/OC-48/OC-192 signal degrade threshold.
........................................................................................................................................................................
Alcatel-Lucent 1665 DMXtend R10.0
365-372-327R10.0 Issue 1
January 2013
click on:
Remote NE Status: Enabled
Leave enough slack in the fibers to allow them to be moved higher or lower to
CAUTION
Equipment damage
The LNW38, LNW40, LNW51, LNW302, LNW382, and LNW601 OLIU circuit
packs are equipped with optics that do not meet GR-78 R9-3 requirements on
ESD susceptibility. Always use proper ESD procedures when handling these
OLIU circuit packs to avoid equipment damage.
The Alcatel-Lucent 1665 DMXtend OLIUs require single-mode lightguide
7 - 5