Sign In
Upload
Manuals
Brands
3Ware Manuals
Controller
9500S
3Ware 9500S Manuals
Manuals and User Guides for 3Ware 9500S. We have
5
3Ware 9500S manuals available for free PDF download: User Manual, Manual, Cli Manual
3Ware 9500S User Manual (272 pages)
Serial ATA RAID Controller 9000 series
Brand:
3Ware
| Category:
Controller
| Size: 3.84 MB
Table of Contents
Table of Contents
3
About this Guide
7
How this Guide Is Organized
7
Conventions
9
Chapter 1. Introducing the 3Ware® 9000 Series Controller
11
Product Models and Features
11
What's New with 9550SX and 9590SE Models
12
System Requirements
13
Understanding RAID Concepts and Levels
15
Available RAID Configurations
16
Determining What RAID Level to Use
19
Support for over 2 Terabytes
21
3Ware Tools for Configuration and Management
22
3BM (3Ware BIOS Manager)
22
3DM 2 (3Ware Disk Manager)
22
3Ware CLI (Command Line Interface)
23
Monitoring, Maintenance, and Troubleshooting Features
23
Chapter 2. Getting Started with Your 3Ware RAID Controller
25
Chapter 3. First-Time RAID Configuration Using 3BM
29
Basic Steps for Creating a Unit
29
Specifying a Hot Spare
37
Leaving Individual Drives as Jbods
37
Checking the Motherboard Boot Sequence
38
What Next
38
Chapter 4. Driver Installation
39
Driver Installation under Windows
40
Materials Required
40
Creating a 3Ware Driver Diskette
41
Installing the 3Ware Driver and Windows on a New Unit
41
Installing the Driver on a System that Boots from a Different Device
42
Making Units Managed by a 3Ware Controller Available to Windows
47
Driver Installation under Linux
48
Obtaining 3Ware Linux Drivers
49
Driver Installation under Red hat Linux or Fedora Core 4
50
Driver Installation under Suse Linux
55
Compiling a 3Ware Driver for Linux
58
Driver Installation under Freebsd
59
Obtaining 3Ware Freebsd Drivers
59
Installing the Driver under Freebsd
60
Chapter 5. 3Ware BIOS Manager 2 (3BM 2)
65
Starting 3BM 2
65
Exiting the 3BM Configuration Utility
67
Working in the 3BM Screens
68
Adjusting BIOS Loading Settings
71
Displaying Controller Information
73
Getting Help While Using 3BM
73
Chapter 6. 3Ware Disk Manager (3DM 2)
75
Browser Requirements for 3DM
76
Setting up Mozilla
76
Installing 3DM
77
Installing 3DM on a Microsoft Windows System
77
Uninstalling 3DM under Microsoft Windows
80
Installing 3DM for Linux or Freebsd
80
Uninstalling 3DM under Linux or Freebsd
82
Starting 3DM and Logging in
83
Starting 3DM under Linux
83
Starting 3DM under Microsoft Windows
83
Viewing 3DM Remotely Via a Standard Web Browser
84
Logging in
85
Working with the 3DM Screens
86
3DM Menus
87
Viewing Information about Different Controllers in 3DM
88
Refreshing the Screen
88
3DM Screens and What They're Used for
88
Setting up 3DM Preferences
90
Setting and Changing 3DM Passwords
90
Managing E-Mail Event Notification
91
Enabling and Disabling Remote Access
92
Setting the Incoming Port
93
Setting the Frequency of Page Refreshes
93
3DM 2 Reference
94
Controller Summary Page
94
Controller Details Page
96
Unit Information Page
97
Unit Details Page
99
Drive Information Page
100
Drive Details Window
102
Controller Settings Page
103
Scheduling Page
108
Maintenance Page
110
Alarms Page
119
Battery Backup Page
120
3DM 2 Settings Page
122
Remote Access
124
Http Settings
124
Chapter 7. Configuring Your Controller
125
Viewing Information about Individual Controllers
125
Viewing and Seting Controller Policies
127
Viewing Controller Policies
128
Setting the Auto-Rebuild Policy
130
Using Auto-Carving for Multi LUN Support
131
Setting the Size of Volumes Created with Auto-Carving
133
Enabling and Setting up Staggered Spin-Up
134
Exporting JBOD Disks
135
Disabling Write Cache on Unit Degrade
136
Chapter 8. Configuring Units
137
Configuring a New Unit
138
Configuration Options When Creating a Unit
138
Creating a Unit through 3DM
140
Creating a Unit through 3BM
143
Ordering Units in 3BM
147
Partitioning and Formatting Units
147
Creating a Hot Spare
149
Specifying a Hot Spare through 3DM
150
Specifying a Hot Spare through 3BM
150
Naming a Unit
151
Setting Unit Policies
152
Enabling and Disabling the Unit Write Cache
153
Setting Auto-Verify for a Unit
155
Setting Continue on Source Error During Rebuild
156
Enabling and Disabling Queuing for a Unit
157
Setting the Storsave Profile for a Unit
159
Setting the Storsave Profile through 3Dm
160
Changing an Existing Configuration
161
RAID Level Migration (RLM) Overview
162
Changing RAID Level
163
Expanding Unit Capacity
164
Informing the Operating System of Changed Configuration
165
Deleting a Unit
167
Deleting a Unit through 3DM
167
Deleting a Unit through 3BM
169
Removing a Unit
171
Removing a Unit through 3DM
171
Removing a Unit through 3BM
172
Moving a Unit from One Controller to Another
173
Unlocking Drives Configured on a 9500S Controller
174
Moving Units from an 8000 Controller to a 9000 Controller
174
Moving Legacy JBOD Units to a 9000 Controller
176
Moving Units from a 9500S to a 9550SX or 9590SE Controller
176
Adding a Drive through 3DM
178
Removing a Drive
179
Rescanning the Controller
181
Chapter 9. Maintaining Units
183
Checking Unit and Drive Status through 3DM
183
Reviewing Alarms and Errors
185
Viewing Alarms
185
Downloading an Error Log
186
Viewing SMART Data about a Drive
186
About Background Tasks
187
About Initialization
187
Initialization of Different RAID Types
188
Auto Initialization after Power Failure
189
About Rebuilds
190
About Verification
191
About Migration
192
About Self-Tests
193
Setting Background Task Rate
193
Scheduling Background Tasks
194
Viewing Current Task Schedules
195
Turning on or off Use of a Task Schedule
196
Removing a Task Schedule
197
Adding a New Task Schedule Slot
198
Selecting Self-Tests to be Performed
198
Rebuilding Units
199
Rebuilding a Unit through 3DM
200
Rebuilding Units through 3BM
201
Cancelling a Rebuild and Restarting It with a Different Drive
204
Verifying Units
204
Locating a Drive by Blinking Its LED
206
Advertisement
3ware 9500S Manual (150 pages)
SAS/SATA RAID Controller
Brand:
3ware
| Category:
Controller
| Size: 1.01 MB
Table of Contents
Raid Controller
1
Copyright Notice
2
Table of Contents
4
About this CLI Guide
9
Chapter 1 Introduction to the 3Ware Command Line Interface
10
Features of the CLI
11
Supported Operating Systems
11
Installing the 3Ware CLI
11
Installing the 3Ware CLI on Windows
12
Installing the 3Ware CLI on Linux, Freebsd, and Opensolaris
13
Working with 3Ware CLI
15
Using the Command Interface Interactively
15
Using a Single Command with Output
16
Using an Input File to Execute a Script
16
Outputting the CLI to a Text File
17
Conventions
17
Understanding RAID Levels and Concepts
18
RAID Concepts
18
Available RAID Configurations
19
Determining What RAID Level to Use
25
Using Drive Capacity Efficiently
26
Support for over 2 Terabytes
27
Chapter 2 CLI Syntax Reference
28
Common Tasks Mapped to CLI Commands
28
Terminology
32
Syntax Overview
33
Shell Object Commands
34
Focus Object
35
Commit
35
Flush
36
Rescan
36
Show
36
Show Alarms [Reverse]
37
Show Events [Reverse]
37
Show Aens [Reverse]
37
Show Diag
37
Show Rebuild
37
Show Selftest
38
Show Ver
39
Show Verify
39
Update Fw=Filename_With_Path [Force]
40
Controller Object Commands
41
CX Show
41
CX Show Attribute [Attribute
45
CX Show Achip
45
CX Show Allunitstatus
45
CX Show Autocarve
45
CX Show Autorebuild
46
CX Show Bios
46
CX Show Carvesize
47
CX Show Ctlbus
47
CX Show Driver
47
CX Show Dpmstat [Type=Inst|Ra|Ext]
47
CX Show Drivestatus
50
CX Show Exportjbod
51
CX Show Firmware
51
CX Show Memory
51
CX Show Model
52
CX Show Monitor
52
CX Show Numdrives
52
CX Show Numports
52
CX Show Numunits
53
CX Show Ondegrade
53
CX Show Pcb
53
CX Show Pchip
53
CX Show Serial
53
CX Show Spinup
54
CX Show Stagger
54
CX Show Unitstatus
54
CX Show All
55
CX Show Alarms [Reverse]
56
CX Show Events [Reverse]
56
CX Show Aens [Reverse]
57
CX Show Diag
57
CX Show Phy
57
CX Show Rebuild
58
CX Show Rebuildmode
60
CX Show Rebuildrate
61
CX Show Selftest
62
CX Show Verify
63
CX Show Verifymode
64
CX Show Verifyrate
65
9
65
Balance
65
Rdcachebasic] [Autoverify] [Noqpolicy] [Ignoreecc] [Name=String]
66
[Storsave=<Protect|Balance|Perform>] [Rapidrecovery=All|Rebuild|Disable]
66
[V0=N|Vol=A:b:C:D]
66
CX Rescan [Noscan]
72
CX Commit
72
CX Flush
72
CX Update Fw=Filename_With_Path [Force]
72
CX Add Rebuild=DDD:hh:duration
74
CX Add Verify=DDD:hh:duration
75
CX Add Selftest=DDD:hh
76
CX del Rebuild=Slot_Id
77
CX del Verify=Slot_Id
77
CX del Selftest=Slot_Id
77
CX Set Dpmstat=On|Off
78
CX Set Rebuild=Enable|Disable|1
78
CX Set Rebuildmode=<Adaptive|Lowlatency
79
CX Set Rebuildrate=<1
80
CX Set Verify=Enable|Disable|1
80
CX Set Verify=Advanced|Basic|1
81
CX Set Verify=Basic [Pref=DDD:hh]
81
CX Set Verifymode=<Adaptive|Lowlatency
82
CX Set Verifyrate=<1
83
CX Set Selftest=Enable|Disable [Task=Udma|Smart]
84
CX Set Exportjbod=On|Off
84
CX Set Ondegrade=Cacheoff|Follow
85
CX Set Spinup=Nn
85
CX Set Stagger=Nn
85
CX Set Autocarve=On|Off
85
CX Set Carvesize=[1024
86
CX Set Autorebuild=On|Off
86
/CX Set Autodetect=On|Off Disk=<P:-P>|All
87
CX Start Mediascan
88
CX Stop Mediascan
88
Unit Object Commands
89
CX/Ux Show
90
CX/Ux Show Attribute [Attribute
92
CX/Ux Show Autoverify
92
CX/Ux Show Cache
92
CX/Ux Show Wrcache
92
CX/Ux Show Rdcache
93
CX/Ux Show Identify
93
CX/Ux Show Ignoreecc
93
CX/Ux Show Initializestatus
93
CX/Ux Show Name
93
CX/Ux Show Qpolicy
94
CX/Ux Show Rapidrecovery
94
CX/Ux Show Rebuildstatus
94
CX/Ux Show Serial
95
CX/Ux Show Status
95
CX/Ux Show Storsave
95
CX/Ux Show Verifystatus
95
CX/Ux Show Volumes
96
CX/Ux Show All
96
CX/Ux Remove [Noscan] [Quiet]
97
CX/Ux del [Noscan] [Quiet]
97
CX/Ux Start Rebuild Disk=<P:-P
98
CX/Ux Start Verify
98
CX/Ux Pause Rebuild
100
CX/Ux Resume Rebuild
100
CX/Ux Stop Verify
100
CX/Ux Flush
100
CX/Ux Set Autoverify=On|Off
100
CX/Ux Set Cache=On|Off [Quiet]
102
CX/Ux Set Wrcache=On|Off [Quiet]
102
CX/Ux Set Rdcache=Basic|Intelligent|Off
102
CX/Ux Set Identify=On|Off
103
CX/Ux Set Ignoreecc=On|Off
104
CX/Ux Set Name=String
104
CX/Ux Set Qpolicy=On|Off
104
CX/Ux Set Rapidrecovery All|Rebuild|Disable [Quiet]
105
CX/Ux Set Storsave=Protect|Balance|Perform [Quiet]
105
9
105
CX/Ux Migrate Type=Raidtype [Disk=P:-P]
107
[Autoverify]
107
Port Object Commands
114
CX/Px Show
114
CX/Px Show Attribute [Attribute
115
CX/Px Show Capacity
115
CX/Px Show Driveinfo
115
CX/Px Show Firmware
116
CX/Px Show Identify
116
CX/Px Show Lspeed
116
CX/Px Show Model
117
CX/Px Show Ncq
117
CX/Px Show Serial
117
CX/Px Show Smart
117
CX/Px Show Status
118
CX/Px Show All
118
CX/Px Show Dpmstat Type=Inst|Ra|Lct|Histdata|Ext
120
CX/Px Remove [Noscan] [Quiet]
122
CX/Px Set Identify=On|Off
123
CX/Px Set Dpmstat=Clear [Type=Ra|Lct|Ext]
123
Phy Object Commands
125
CX/Phyx Show
125
CX/Phyx Set Link=Auto|1.5|3.0
125
BBU Object Commands
126
CX/Bbu Show
126
CX/Bbu Show Attribute [Attribute
127
CX/Bbu Show Batinst
127
CX/Bbu Show Bootloader
127
CX/Bbu Show Cap
127
CX/Bbu Show Fw
127
CX/Bbu Show Lasttest
127
CX/Bbu Show Pcb
127
CX/Bbu Show Serial
128
CX/Bbu Show Status
128
CX/Bbu Show Temp
129
CX/Bbu Show Volt
129
CX/Bbu Show All
129
CX/Bbu Test [Quiet]
130
CX/Bbu Enable
130
CX/Bbu Disable [Quiet]
130
Enclosure Object and Element Commands
131
CX/Ex Show
132
CX/Ex Show Attribute [Attribute
133
CX/Ex Show Controllers
133
CX/Ex/ Show Diag=Helptext
133
CX/Ex Show Slots
134
CX/Ex Show Fans
134
CX/Ex Show Temp
135
CX/Ex Show Pwrs
135
CX/Ex Show Alarms
136
CX/Ex Show All
136
CX/Ex/Slotx Show
136
CX/Ex/Slotx Show Identify
137
CX/Ex/Slotx Set Identify=On|Off
137
CX/Ex/Fanx Show
138
CX/Ex/Fanx Show Identify
138
CX/Ex/Fanx Set Identify=On|Off
138
CX/Ex/Fanx Set Speed=<0
138
CX/Ex/Pwrsx Show
139
CX/Ex/Pwrsx Show Identify
139
CX/Ex/Pwrsx Set Identify=On|Off
140
CX/Ex/Tempx Show
140
CX/Ex/Tempx Show Identify
140
CX/Ex/Tempx Set Identify=On|Off
141
CX/Ex/Almx Show
141
CX/Ex/Almx Set Alarm=Mute|Unmute|Off
141
Help Commands
142
Help with Specific Commands
142
Help with Attributes
144
Help
144
Help Show
145
Help Flush
145
Help Rescan
145
Help Update
146
Help Commit
146
Help Focus
146
Help /CX
146
Help /CX/Phyx
146
Help /CX/Ux
146
Help /CX/Px
146
Help /CX/Bbu
147
Help /CX/Ex
147
Help /CX/Ex/Slotx
147
Help /CX/Ex/Fanx
147
Help /CX/Ex/Tempx
147
Help /CX/Ex/Pwrsx
147
Help /CX/Ex/Almx
148
Command Logging
148
Location of the Log File
148
Disabling and Enabling Command Logging
149
Return Code
150
3ware 9500S Manual (122 pages)
9000 Series Serial ATA RAID Controller
Brand:
3ware
| Category:
Controller
| Size: 0.58 MB
Table of Contents
Command Line Interface
1
Table of Contents
3
About this Guide
9
How this Guide Is Organized
9
Chapter 1. Introduction to the 3Ware Command Line Interface
11
Features
11
Supported Operating Systems
12
Terminology
12
Installing the 3Ware CLI
13
Installing the 3Ware CLI on Windows
13
Installing the 3Ware CLI on Linux and Freebsd
14
Working with 3Ware CLI
15
Using the Command Interface Interactively
15
Using a Single Command with Output
16
Using an Input File to Execute a Script
16
Outputting the CLI to a Text File
17
Conventions
17
Understanding RAID Concepts and Levels
18
Available RAID Configurations
19
Determining What RAID Level to Use
22
Storsave Profiles
24
Chapter 2. Primary CLI Syntax Reference
27
Common Tasks Mapped to CLI Commands
27
Primary Syntax Overview
29
Shell Object Commands
31
Focus Object
31
Show
32
Show Ver
33
Show Alarms [Reverse]
33
Show Diag
33
Show Rebuild
33
Show Verify
34
Show Selftest
34
Flush
35
Rescan
35
Commit
35
Controller Object Commands
36
CX Show
37
CX Show Attribute [Attribute
38
CX Show Driver
38
CX Show Model
38
CX Show Firmware
38
CX Show Bios
39
CX Show Monitor
39
CX Show Serial
39
CX Show Pcb
39
CX Show Pchip
39
CX Show Achip
39
CX Show Numports
40
CX Show Numunits
40
CX Show Numdrives
40
CX Show Exportjbod
40
CX Show Spinup
40
CX Show Stagger
41
CX Show Ondegrade
41
CX Show Autocarve
41
CX Show Carvesize
42
CX Show Memory
42
CX Show Autorebuild
42
CX Show Unitstatus
43
CX Show Allunitstatus
43
CX Show Drivestatus
43
CX Show All
44
[Storsave=<Protect|Balance|Perform>]
45
Nocache] [Autoverify] [Ignoreecc] [Name=String Storsave=<Protect|Balance|Perform>]
45
CX Rescan [Noscan]
47
CX Commit
48
CX Flush
48
CX Show Alarms [Reverse]
48
CX Show Diag
49
CX Show Rebuild
49
CX Show Verify
51
CX Show Selftest
52
CX Add Rebuild=DDD:hh:duration
53
CX Add Verify=DDD:hh:duration
54
CX Add Selftest=DDD:hh
55
CX del Rebuild=Slot_Id
56
CX del Verify=Slot_Id
56
CX del Selftest=Slot_Id
56
CX Set Rebuild=Enable|Disable|1
56
CX Set Verify=Enable|Disable|1
57
CX Set Selftest=Enable|Disable [Task=Udma|Smart]
57
/CX Set Exportjbod=On|Off
57
/CX Set Ondegrade=Cacheoff|Follow
58
CX Set Spinup=Nn
58
CX Set Stagger=Nn
58
/CX Set Autocarve=On|Off
58
CX Set Carvesize=[1024
59
/CX Set Autorebuild=On|Off
59
CX Start Mediascan
60
CX Stop Mediascan
60
Unit Object Commands
61
CX/Ux Show
61
CX/Ux Show Attribute [Attribute
62
CX/Ux Show Status
62
CX/Ux Show Rebuildstatus
62
CX/Ux Show Verifystatus
63
CX/Ux Show Initializestatus
63
CX/Ux Show Name
63
CX/Ux Show Serial
63
CX/Ux Show Qpolicy
63
CX/Ux Show Storsave
64
CX/Ux Show Volumes
64
CX/Ux Show All
64
CX/Ux Export [Noscan] [Quiet]
65
CX/Ux del [Noscan] [Quiet]
65
CX/Ux Start Rebuild Disk=P<P:-P
66
CX/Ux Start Verify
66
CX/Ux Pause Rebuild
67
CX/Ux Resume Rebuild
67
CX/Ux Stop Verify
67
CX/Ux Flush
67
/CX/Ux Set Autoverify=On|Off
67
CX/Ux Set Cache=On|Off [Quiet]
68
/CX/Ux Set Ignoreecc=On|Off
68
CX/Ux Set Name=String
69
/CX/Ux Set Qpolicy=On|Off
69
/CX/Ux Set Storsave=Protect|Balance|Perform
69
CX/Ux Migrate Type=Raidtype [Disk=P:-P] [Group=3|4|5|6] [Stripe=Stripe] [Noscan] [Nocache][Autoverify]
70
Port Object Commands
75
CX/Px Show
75
CX/Px Show Attribute [Attribute
75
CX/Px Show Status
75
CX/Px Show Model
76
CX/Px Show Serial
76
CX/Px Show Firmware
76
CX/Px Show Identify
76
CX/Px Show Ncq
76
CX/Px Show Lspeed
77
CX/Px Show Capacity
77
CX/Px Show Smart
77
CX/Px Show All
78
CX/Px Export [Noscan] [Quiet]
78
/CX/Px Set Identify=On|Off
79
BBU Object Commands
80
CX/Bbu Show
80
CX/Bbu Show Attribute [Attribute
81
CX/Bbu Show Status
81
CX/Bbu Show Batinst
81
CX/Bbu Show Lasttest
82
CX/Bbu Show Volt
82
CX/Bbu Show Temp
82
CX/Bbu Show Cap
82
CX/Bbu Show Serial
82
CX/Bbu Show Fw
82
CX/Bbu Show Pcb
83
CX/Bbu Show Bootloader
83
CX/Bbu Show All
83
CX/Bbu Test [Quiet]
83
CX/Bbu Enable
84
CX/Bbu Disable
84
Help Commands
84
Help with Specific Commands
84
Help with Attributes
85
CX del Rebuild=Slot_Id
85
Help
86
Help Show
86
Help Flush
87
Help Rescan
87
Help Commit
87
Help Focus
87
Help /CX
87
Help /CX/Ux
87
Help /CX/Px
87
Help /CX/Bbu
87
Environment Variables
88
Return Code
88
Advertisement
3ware 9500S Manual (135 pages)
SAS/SATA RAID Controller
Brand:
3ware
| Category:
Controller
| Size: 0.71 MB
Table of Contents
Raid Controller
1
Table of Contents
3
About this CLI Guide
8
Chapter 1 Introduction to the 3Ware Command Line Interface
9
Features of the CLI
10
Supported Operating Systems
10
Installing the 3Ware CLI
10
Installing the 3Ware CLI on Windows
11
Installing the 3Ware CLI on Linux and Freebsd
12
Working with 3Ware CLI
13
Using the Command Interface Interactively
14
Using a Single Command with Output
14
Using an Input File to Execute a Script
15
Outputting the CLI to a Text File
15
Conventions
16
Understanding RAID Levels and Concepts
16
RAID Concepts
17
Available RAID Configurations
18
Determining What RAID Level to Use
24
Using Drive Capacity Efficiently
25
Support for over 2 Terabytes
26
Chapter 2 CLI Syntax Reference
27
Common Tasks Mapped to CLI Commands
27
Terminology
30
Syntax Overview
31
Shell Object Commands
33
Focus Object
33
Commit
34
Flush
34
Rescan
34
Show
34
Show Alarms [Reverse]
35
Show Diag
35
Show Rebuild
36
Show Selftest
36
Show Ver
37
Show Verify
37
Update Fw=Filename_With_Path [Force]
38
Controller Object Commands
39
CX Show
39
CX Show Attribute [Attribute
42
CX Show Achip
42
CX Show Allunitstatus
43
CX Show Autocarve
43
CX Show Autorebuild
43
CX Show Bios
44
CX Show Carvesize
44
CX Show Ctlbus
44
CX Show Driver
44
CX Show Dpmstat [Type=Inst|Ra|Ext]
45
CX Show Drivestatus
48
CX Show Exportjbod
49
CX Show Firmware
49
CX Show Memory
50
CX Show Model
50
CX Show Monitor
50
CX Show Numdrives
50
CX Show Numports
51
CX Show Numunits
51
CX Show Ondegrade
51
CX Show Pcb
51
CX Show Pchip
51
CX Show Serial
52
CX Show Spinup
52
CX Show Stagger
52
CX Show Unitstatus
52
CX Show All
53
CX Show Alarms [Reverse]
54
CX Show Diag
55
CX Show Phy
55
CX Show Rebuild
56
Version
56
P3 OK U0
57
P5 OK
57
P6 NOT-PRESENT
57
P0 NOT-PRESENT
57
CX Show Selftest
58
P6 NOT-PRESENT
58
CX Show Verify
59
[Rapidrecovery=All|Rebuild|Disable] [V0=N|Vol=A:b:C:D]
61
CX Rescan [Noscan]
66
CX Commit
67
CX Flush
67
CX Update Fw=Filename_With_Path [Force]
67
CX Add Rebuild=DDD:hh:duration
69
CX Add Verify=DDD:hh:duration
70
CX Add Selftest=DDD:hh
71
CX del Rebuild=Slot_Id
72
CX del Verify=Slot_Id
72
CX del Selftest=Slot_Id
72
CX Set Dpmstat=On|Off
73
CX Set Rebuild=Enable|Disable|1
73
CX Set Verify=Enable|Disable|1
74
CX Set Verify=Advanced|Basic|1
74
CX Set Verify=Basic [Pref=DDD:hh]
74
CX Set Selftest=Enable|Disable [Task=Udma|Smart]
76
CX Set Exportjbod=On|Off
76
CX Set Ondegrade=Cacheoff|Follow
76
CX Set Spinup=Nn
77
CX Set Stagger=Nn
77
CX Set Autocarve=On|Off
77
CX Set Carvesize=[1024
78
CX Set Autorebuild=On|Off
78
/CX Set Autodetect=On|Off Disk=<P:-P>|All
79
CX Start Mediascan
80
CX Stop Mediascan
80
Unit Object Commands
81
CX/Ux Show
82
CX/Ux Show Attribute [Attribute
84
CX/Ux Show Autoverify
84
CX/Ux Show Cache
84
CX/Ux Show Identify
84
CX/Ux Show Ignoreecc
85
CX/Ux Show Initializestatus
85
CX/Ux Show Name
85
CX/Ux Show Qpolicy
85
CX/Ux Show Rapidrecovery
86
CX/Ux Show Rebuildstatus
86
CX/Ux Show Serial
86
CX/Ux Show Status
87
CX/Ux Show Storsave
87
CX/Ux Show Verifystatus
87
CX/Ux Show Volumes
87
CX/Ux Show All
88
CX/Ux Remove [Noscan] [Quiet]
89
CX/Ux del [Noscan] [Quiet]
89
CX/Ux Start Rebuild Disk=P<P:-P
90
CX/Ux Start Verify
90
CX/Ux Pause Rebuild
91
CX/Ux Resume Rebuild
92
CX/Ux Stop Verify
92
CX/Ux Flush
92
CX/Ux Set Autoverify=On|Off
92
CX/Ux Set Cache=On|Off [Quiet]
93
CX/Ux Set Identify=On|Off
94
CX/Ux Set Ignoreecc=On|Off
94
CX/Ux Set Name=String
95
CX/Ux Set Qpolicy=On|Off
95
CX/Ux Set Rapidrecovery All|Rebuild|Disable [Quiet]
95
CX/Ux Set Storsave=Protect|Balance|Perform [Quiet]
96
9
96
CX/Ux Migrate Type=Raidtype [Disk=P:-P]
97
[Autoverify]
97
Port Object Commands
104
CX/Px Show
104
CX/Px Show Attribute [Attribute
105
CX/Px Show Capacity
105
CX/Px Show Driveinfo
105
CX/Px Show Firmware
106
CX/Px Show Identify
106
CX/Px Show Lspeed
106
CX/Px Show Model
106
CX/Px Show Ncq
107
CX/Px Show Serial
107
CX/Px Show Smart
107
CX/Px Show Status
108
CX/Px Show All
108
CX/Px Show Dpmstat Type=Inst|Ra|Lct|Histdata|Ext
109
CX/Px Remove [Noscan] [Quiet]
112
CX/Px Set Identify=On|Off
112
CX/Px Set Dpmstat=Clear [Type=Ra|Lct|Ext]
113
Phy Object Commands
114
CX/Phyx Show
114
CX/Phyx Set Link=Auto|1.5|3.0
114
BBU Object Commands
115
CX/Bbu Show
115
CX/Bbu Show Attribute [Attribute
116
CX/Bbu Show Batinst
116
CX/Bbu Show Bootloader
116
CX/Bbu Show Cap
116
CX/Bbu Show Fw
116
CX/Bbu Show Lasttest
116
CX/Bbu Show Pcb
116
CX/Bbu Show Serial
117
CX/Bbu Show Status
117
CX/Bbu Show Temp
118
CX/Bbu Show Volt
118
CX/Bbu Show All
118
CX/Bbu Test [Quiet]
119
CX/Bbu Enable
119
CX/Bbu Disable [Quiet]
119
Enclosure Object and Element Commands
120
CX/Ex Show
121
CX/Ex Show Attribute [Attribute
122
CX/Ex Show Controllers
122
CX/Ex/ Show Diag=Helptext
122
CX/Ex Show Slots
122
CX/Ex Show Fans
123
CX/Ex Show Temp
123
CX/Ex Show Pwrs
124
CX/Ex Show All
124
CX/Ex/Slotx Show
124
CX/Ex/Slotx Show Identify
125
CX/Ex/Slotx Set Identify=On|Off
125
CX/Ex/Fanx Show
125
CX/Ex/Fanx Show Identify
126
CX/Ex/Fanx Set Identify=On|Off
126
CX/Ex/Pwrsx Show
126
CX/Ex/Pwrsx Show Identify
127
CX/Ex/Pwrsx Set Identify=On|Off
127
CX/Ex/Tempx Show
127
CX/Ex/Tempx Show Identify
128
CX/Ex/Tempx Set Identify=On|Off
128
Help Commands
128
Help with Specific Commands
129
Help with Attributes
130
Help
131
Help Show
131
Help Flush
131
Help Rescan
132
Help Update
132
Help Commit
132
Help Focus
132
Help /CX
132
Help /CX/Phyx
132
Help /CX/Ux
132
Help /CX/Px
133
Help /CX/Bbu
133
Help /CX/Ex
133
Help /CX/Ex/Slotx
133
Help /CX/Ex/Fanx
133
Help /CX/Ex/Tempx
133
Help /CX/Ex/Pwrsx
134
Command Logging
134
Return Code
135
3Ware 9500S Cli Manual (103 pages)
Serial ATA RAID Controller
Brand:
3Ware
| Category:
Computer Hardware
| Size: 0.55 MB
Table of Contents
Raid Controller
1
Table of Contents
3
About this CLI Guide
7
Chapter 1 Introduction to the 3Ware Command Line Interface
8
Features of the CLI
8
Supported Operating Systems
9
Terminology
9
Installing the 3Ware CLI
10
Installing the 3Ware CLI on Mac os X
10
Installing the 3Ware CLI on Windows
10
Installing the 3Ware CLI on Linux and Freebsd
12
Working with 3Ware CLI
13
Using the Command Interface Interactively
13
Using a Single Command with Output
14
Using an Input File to Execute a Script
14
Outputting the CLI to a Text File
15
Conventions
15
Understanding RAID Levels and Concepts
16
RAID Concepts
16
Available RAID Configurations
17
Determining What RAID Level to Use
23
Chapter 2 CLI Syntax Reference
26
Common Tasks Mapped to CLI Commands
26
Syntax Overview
28
Shell Object Commands
30
Focus Object
30
Show
31
Show Ver
32
Show Alarms [Reverse]
32
Show Diag
32
Show Rebuild
32
Show Verify
33
Show Selftest
34
Flush
34
Rescan
34
Commit
34
Update Fw=Filename_With_Path [Force]
34
Controller Object Commands
35
CX Show
35
CX Commit
36
CX Flush
36
CX Show Attribute [Attribute
37
CX Show Driver
38
CX Show Model
38
CX Show Firmware
38
CX Show Bios
38
CX Show Monitor
38
CX Show Serial
39
CX Show Pcb
39
CX Show Pchip
39
CX Show Autocarve
42
CX Show Autorebuild
43
Group=<3|4|5|6|7|8|9|10|11|12>] [Nocache] [Autoverify] [Noqpolicy][Ignoreecc Name=String] [Storsave=<Protect|Balance|Perform>]
43
CX Show All
45
CX Rescan [Noscan]
49
CX Update Fw=Filename_With_Path [Force]
50
CX Show Alarms [Reverse]
51
CX Show Diag
52
CX Show Rebuild
52
CX Show Verify
54
CX Show Selftest
55
CX Add Rebuild=DDD:hh:duration
56
CX Add Verify=DDD:hh:duration
57
CX Add Selftest=DDD:hh
58
CX del Rebuild=Slot_Id
59
CX del Verify=Slot_Id
59
CX del Selftest=Slot_Id
59
CX Set Rebuild=Enable|Disable|1
59
CX Set Verify=Enable|Disable|1
60
CX Set Selftest=Enable|Disable [Task=Udma|Smart]
60
CX Set Exportjbod=On|Off
61
CX Set Ondegrade=Cacheoff|Follow
61
CX Set Spinup=Nn
61
CX Set Stagger=Nn
62
CX Set Autocarve=On|Off
62
CX Set Carvesize=[1024
62
CX Set Autorebuild=On|Off
63
CX Set Autodetect=On|Off Disk=<P:-P>|All
63
CX Start Mediascan
64
CX Stop Mediascan
65
Unit Object Commands
65
CX/Ux Show
66
CX/Ux Show Attribute [Attribute
67
CX/Ux Show Status
67
CX/Ux Show Rebuildstatus
67
CX/Ux Show Verifystatus
67
CX/Ux Show Initializestatus
68
CX/Ux Show Name
68
CX/Ux Show Serial
68
CX/Ux Show Qpolicy
68
CX/Ux Show Storsave
69
CX/Ux Show Identify
69
CX/Ux Show Autoverify
69
CX/Ux Show Cache
69
CX/Ux Show Ignoreecc
70
CX/Ux Show Volumes
70
CX/Ux Show All
70
CX/Ux Remove [Noscan] [Quiet]
71
CX/Ux del [Noscan] [Quiet]
72
CX/Ux Start Rebuild Disk=P<P:-P
72
CX/Ux Start Verify
73
CX/Ux Pause Rebuild
73
CX/Ux Resume Rebuild
73
CX/Ux Stop Verify
74
CX/Ux Flush
74
CX/Ux Set Autoverify=On|Off
74
CX/Ux Set Cache=On|Off [Quiet]
74
CX/Ux Set Identify=On|Off
75
CX/Ux Set Ignoreecc=On|Off
75
CX/Ux Set Name=String
76
CX/Ux Set Qpolicy=On|Off
76
CX/Ux Set Storsave=Protect|Balance|Perform [Quiet]
76
CX/Ux Migrate Type=Raidtype [Disk=P:-P]
78
Port Object Commands
83
CX/Px Show
83
CX/Px Show Attribute [Attribute
83
CX/Px Show Status
84
CX/Px Show Model
84
CX/Px Show Serial
84
CX/Px Show Firmware
84
CX/Px Show Identify
84
CX/Px Show Ncq
85
CX/Px Show Lspeed
85
CX/Px Show Capacity
85
CX/Px Show Smart
85
CX/Ux Migrate Type=Raidtype [Disk=P:-P Group=3|4|5|6|7|8|9|10|11|12] [Stripe=Stripe] [Noscan] [Nocache] [Autoverify]
85
CX/Px Show All
86
CX/Px Remove [Noscan] [Quiet]
87
CX/Px Set Identify=On|Off
87
BBU Object Commands
88
CX/Bbu Show
88
CX/Bbu Show Attribute [Attribute
89
CX/Bbu Show Status
89
CX/Bbu Show Batinst
90
CX/Bbu Show Lasttest
90
CX/Bbu Show Volt
90
CX/Bbu Show Temp
90
CX/Bbu Show Cap
90
CX/Bbu Show Serial
91
CX/Bbu Show Fw
91
CX/Bbu Show Pcb
91
CX/Bbu Show Bootloader
91
CX/Bbu Show All
91
CX/Bbu Test [Quiet]
92
CX/Bbu Enable
92
CX/Bbu Disable [Quiet]
92
Enclosure Object Commands
93
Ex Show
93
Ex Show Attribute [Attribute
94
Ex Show Controllers
94
Ex Show Slots
95
Ex Show Fans
95
Ex Show Temp
95
Ex Show All
95
Ex/Slotx Show
96
Ex/Slotx Show Identify
96
Ex/Slotx Set Identify=On|Off
96
Ex/Fanx Show
97
Ex/Tempx Show
97
Help Commands
97
Help with Specific Commands
97
Help with Attributes
99
Help
99
Help Show
100
Help Flush
100
Help Rescan
100
Help Update
100
Help Commit
100
Help Focus
101
Help /CX
101
Help /CX/Ux
101
Help /CX/Px
101
Help /CX/Bbu
101
Help /Ex
101
Help /Ex/Slotx
101
Help /Ex/Fanx
102
Help /Ex/Tempx
102
Command Logging
102
Return Code
102
Advertisement
Related Products
3Ware 9500S-4LP - Escalade RAID Controller
3Ware 9500S-8MI - Escalade RAID Controller
3Ware 9500S-12 - Escalade RAID Controller
3Ware 9500S-4LPa
3Ware 9500S-8MIb
3Ware 9500S-12MI - Escalade RAID Controller
3Ware 9550SX-4LP - Scalade RAID Controller
3Ware 9550SXU-8LP - Storage Controller - SATA-300
3Ware 9550SXU-16ML - Sata Rohs
3Ware 9550SXU-12 - PCI-X-to-Serial ATA II Hardware RAID Controller
3Ware Categories
Controller
Computer Hardware
Storage
Network Card
Enclosure
More 3Ware Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL