7. Use a T-10 driver to remove and retain the screw on the
microswitch (see Figure 133) and then pull the microswitch off the
alignment pin on the standard valve.
NOTE: You do not have to detach the wires connected to the
microswitch terminals if you are just servicing the standard valve.
8. Replace the standard valve if needed.
Gas Leaks
With electrical power off, carefully check for gas leaks at each gas
component that was removed, replaced, or otherwise serviced using a
gas leak detector (electronic leak detectors are highly recommended)
or bubble test.
Figure 133: Standard Valve with Microswitch on Manifold
1
Screw connecting microswitch to standard valve
58300000163852_ARA_EN_C
6.9.3

Microswitch Removal and Replacement

The microswitches are for the standard burners only, and are
accessed from the top and front of the range.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 134: Microswitch
1. Follow all safety precautions and steps in Preparing the Range for
Servicing, page 25.
2. Follow all steps in Accessing Components under the Maintop,
page 25.
3. Remove the control panel (see Control Panel Removal and
Replacement, page 35).
4. First, make a note of how the wire connectors are attached to
each terminal on the microswitch, and then detach the wire
connectors.
NOTE: It is always recommended to label and tag all wires, wire
connectors and harnesses prior to disconnecting them, so as to
correctly identify their connections/locations when reassembling.
Alternatively, you can photograph the wire connections prior to
disconnecting (for example, with your mobile phone).
5. Use a T-10 driver to remove and retain the screw on the
microswitch (see Figure 133), and then pull the microswitch off the
alignment pin on the standard valve.
6. Replace the microswitch if needed.