Port Status Leds - MCK EXTender PBXgateway II System Administrator Manual

Citel extender pbxgateway ii: user guide
Hide thumbs Also See for EXTender PBXgateway II:
Table of Contents

Advertisement

Table 10:
Error Conditions
Error Condition
DRAM Test failed
Selftest Diagnostic Error
Not Enabled
No Device Connected:
DCE Ready
Table 11:
Normal Conditions
Normal Condition
Carrier Up
Remote Up
Remote test

Port Status LEDs

The PBXgateway II has twenty-four LEDs indicating the status of the user phones (Branch unit) or
PBX/KSU/DEFINITY ports (PBXgateway II).
Table 12:
Port Status LEDs
LED
Off
Meaning
Port is
disabled
1
1
See "Enable the Phone port as follows:" below.
2
See "Check the following:" on the next page.
Enable the Phone port as follows:
1. Connect the Gateway or Branch unit to the Management Interface (MI). See page 58.
2. Navigate to the Port menu using the following path:
->Configuration->Port
3. Check the "Enabled" field indicates "YES" or if the field is set to
<Default>, check that the default setting has all ports enabled.
PBXgateway II System Administrator's Guide
Description
This indicates that one or all of the four DRAM tests have failed.
This hardware failure condition can be caused by a faulty internal
DRAM chip. Recycle the power on the unit and contact MCK if the
light remains "Red".
This indicates that there is a problem with a selftest, indicating a
possible hardware problem. Recycle the power on the unit and
contact MCK if the light remains "Yellow".
Enable the WAN port, if the WAN port is needed. (See Chapter 4 -
Enabling/Disabling WAN Ports for information.)
Check the wiring and cable pinouts between both units and the
network device. (See page 49 for pinout information.)
Check the cable.
Device connected but no network link to the alternate site. Possible
a network error between devices. Check all cables and power to
the units.
Description
Network link established. Try to establish a phone connection from
the Remote unit.
Phone at the remote site is online.
This test sends packets to the alternate site to check the network
condition.
Solid
Slow
Green
Green
Flash
Port is
Extended,
enabled,
and user is
but not
on-hook
extended
(phone is not
in use).
Fast
Reverse
Green
Slow Green
Flash
Flash
Extended and
Call Suspend
the user is off-
Enabled
hook. (phone
is in use)
ConneX
Enabled
Green
Flicker
Port is enabled,
there is a bad
connection to the
2
PBX or phones
.
145