Pilot Lamp Test
Models 40 and 50 EFGO, EFTO type are equipped with a pilot lamp
mounted on the front surface of the lower engine cover. The pilot
lamp illuminates to alert the operator of a low oil level in the oil
automixing tank.
Disable the ignition system to prevent accidental
engine startup.
1. Turn the main switch key to the ON position.
2. Remove the cover from the electrical box.
3. Disconnect the oil level sensor bullet connector.
4. Connect the main switch side of the bullet connector to a clean
engine ground and verify the pilot lamp illuminates. If the lamp does
not illuminate, but other electrical components are functioning
properly, the lamp or wiring may be faulty. Repair or replace as
needed.