Installation
Install in reverse order of removal.
Disconnect negative battery cable from battery
before installing pulser coil assembly.
Use threadlocker on screw threads before installing
screws.
Coil Plate Assembly
Disconnect negative battery cable from battery
before removing coil plate assembly.
On models 40 / 50 / 60B / 70B / 60C / 70C / 80 / 90
the pulser coils cannot be replaced individually. You
must replace the entire coil plate assembly.
On models 115 / 120 / 140 the pulser coils cannot be
replaced individually. You must replace the pulser
coil assembly (see previous procedure).
Removal (models 40D / 50D / 60B / 70B / 60C / 70C / 80 / 90)
1. Remove the flywheel.
3-/ 4-Cylinder
NOTE
NOTE
ELECTRICAL SYSTEM
7-67