TOHATSU 40 Service Manual page 212

2 stroke
Hide thumbs Also See for 40:
Table of Contents

Advertisement

5. For models 40 / 50 / 60C / 70C / 80 / 90 / 115 / 120 / 140:
11
Set the analog multimeter to "400" on the "DVA" scale.
Connect the RED tester lead to terminal (6) and BLACK tester lead
to terminal (4).
Black Lead
Terminal 4
For models 60B and 70B: Set the analog multimeter to "20" (Test 1)
and "200" (Test 2) on the "DVA" scale. Connect the RED and
BLACK tester leads as follows to check the output voltage (DVA) of
the exciter coil at cranking speed:
Black Lead
Test 1 - Terminal 8
Test 2 - Terminal 4
3-/ 4-Cylinder
ELECTRICAL SYSTEM
T1479
Red Lead
Terminal 6
Red Lead
Test 1 - Terminal 6
Test 2 - Terminal 6
7-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

5060708090115 ... Show all

Table of Contents