Multi-stage dry vacuum pump

Advertisement

When an ALARM output is suddenly generated, while the plant unit is
operational, a WARNING signal will be generated to ensure that the plant
operation is not discontinued. This enables the operator to check the pump after
the equivalent of one cycle has been completed.
Be sure to contact EBARA Corporation for details on checking the WARNING
and ALARM setting conditions.
• Note that the warning indications of the Model ESA25-D dry pump are
different from the conventional pumps like as UERR, A, AA, AAS series,
based on SEMI standard E-73.
(Pump operation continued)

3.2.2 Operation Status Control

The sensor data are displayed on the LCD display provided on the controller to
facilitate operation status control and daily inspection.
All WARNING and ALARM signals are displayed on the LCD display. For remote
operation and monitoring, the signals are available as individual and group
outputs.

3.3 The way of pump moving

3.3.1 Preparation

Before pump moving, all adjuster feet shall be raised fully at four places.
In case of being not raised fully, pump may be tripped over by obstacle on floor.
PM10U
Alarm 1
Alarm 2
(Pump stop)
fully
raised
UERR,A,AA,
Model
and AAS
ESA25-D
ALARM
WARNING
TRIP
ALARM
Caster
Adjuster foot
P.5
EBARA
CORPORATION