Download Print this page

Advertisement

Quick Links

CALL 1-800-577-8111 FOR SALES AND SUPPORT
M o d e l E P D , E P P D
Instruction and Operation Manual
P R O D r a i n e r
S u b m e r s i b l e P u m p s
EBARA International Corporation Standard Pump Division
CALL 1-800-577-8111 FOR SALES AND SUPPORT

Advertisement

loading

Summary of Contents for EBARA EPD

  • Page 1 Instruction and Operation Manual P R O D r a i n e r S u b m e r s i b l e P u m p s EBARA International Corporation Standard Pump Division CALL 1-800-577-8111 FOR SALES AND SUPPORT...
  • Page 2 CALL 1-800-577-8111 FOR SALES AND SUPPORT Thank you for purchasing this Ebara Stainless Steel Sump Pump. We hope you are pleased with your purchase and that our pumps will provide you with long service life and exceptional performance. To ensure satisfactory service life, there are several consid- erations regarding proper installation, operation and power source.
  • Page 3 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Important Safeguards To reduce risk of injury, always follow these instructions and safety precautions when using this pump and to maintain warranty. Read All Instructions Prior to Installation (SAVE THESE INSTRUCTIONS) Installation/Operation: •...
  • Page 4 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Important Safeguards Proper Lifting: A separate chain or rope should be attached to the handle for normal lifting. Please note that this will help prevent damage due to inadvertent lifting of the pump by the power cord.
  • Page 5 Plumbing and electrical contractors could advise you on proper installations of drain tiles, sump, pump and electrical service. EBARA recommends that a solid sump base be provided. The sump is fed by drain tile placed around the outside and/or inside base- ment walls at the footings.
  • Page 6 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD General Application Information (cont.) safety reasons. You should never touch a sump pump or discharge piping while the pump is connected to electrical power and water is present. The pump should be disconnected from the electrical source before handling in all cases.
  • Page 7 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD General Application Information (cont.) Basin and Cover The basin should not be less than 18 inches in diameter and 24 inches deep. Larger diameters are advisable in instances of increased pump capacity requirements:...
  • Page 8 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Specifications CAUTION Be careful not to exceed the given specifications in the use of your products. Check the nameplate for your pump’s head (HEAD), discharge volume (CAPACITY), speed (SPEED), motor voltage and current. Other specifications are noted in the chart below: ITEM NO.
  • Page 9 Step 2: Attach desired length of PVC or ABS discharge pipe to pump outlet, using PVC adapter (1 " pipe and adapter for EPPD-3 & EPD-3 1 " for EPD-5, 7, 10 & 15). Make sure open end of pipe will be above top of basin.
  • Page 10 6. Before installing pump, clear sump basin of any water, debris, or sediment. WARN- ING: Sump basin must be vented in accordance with local plumbing codes. EBARA PRO•DRAINERS are not designed for and CANNOT be installed in locations classified as hazardous in the National Electric Code, ANSI/NFPA 70.
  • Page 11 Refer to the installation illustration on the following page for the following instructions. Be certain sump basin is clean and all power to pump is shut off. If pump fails to operate prop- erly after installation, refer to the troubleshooting checklist on page 12 or contact EBARA. General Materials Needed •...
  • Page 12 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD PRO Drainer Submersible Installation Diagram Grounded type 115 volt receptacle min. height above floor – 4 ft. " check valve with rubber sleeve connectors for " and 1 " pipe shut-off gate valve...
  • Page 13 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Motor Wiring Diagram Manual Operation Type Output (Single Phase) • Output Manual Operation Type Output (Three Phase) • Output to 1 Automatic Operation Type Output (Single Phase) • Output CALL 1-800-577-8111 FOR SALES AND SUPPORT...
  • Page 14 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Electrical Wiring – Three Phase WARNING Check that the power is locked off and disconnected before working on pump. All electric work should be performed by a qualified electrician and all national and local electrical codes must be observed.
  • Page 15 Automatic Float Switch Mechanical Float * ITEM NO. EPPD-3AS1 Model No. 32Z707AU6.3S – Impeller/Diffuser material is Thermo Plastic- Noryl GFN2 ** EPPD-3AS1 & EPD-3AS1 – HP Shaft Seal is Non-Mechanical Double Oil Seal (Rubber) CALL 1-800-577-8111 FOR SALES AND SUPPORT...
  • Page 16 '' – 20 Ft. length * ITEM NO. EPPD-3MS1 Model No. 32Z707U6.3S – Impeller/Diffuser material is Thermo Plastic-Noryl GFN3 ** EPPD-3MS1 & EPD-3MS1 – HP Shaft Seal is Non-Mechanical - Double Oil Seal (Rubber) † Three Phase models require user to provide motor protection...
  • Page 17 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Nameplate & Model No./Item No. Explanation EPD SERIES PRO•DRAINER NAME PLATE ITEM No. DESIGNATION: EBARA PUMP ① No. (Serial Number) EXAMPLE: ➁ Model ➂ ➄ CAP. USGPM ➃ ➅ HEAD ➆ PHASE INDUCTION MOTOR ➇...
  • Page 18 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Troubleshooting Checklist PROBLEM POSSIBLE CAUSES • Line circuit breaker is off, or fuse is blown or loose. Pump does not run or • Water level in sump has not reached turn-on level as indicated in hums.
  • Page 19 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Maintenance and Service WARNING: Pump warranty becomes void if you remove motor housing, unscrew impeller, or otherwise remove impeller seal. If pump does not operate properly, follow the steps shown under Troubleshooting.
  • Page 20 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Sectional View – Z707U Automatic Type Output 1/3 HP (Single Phase) Recommended spare parts Part No. Part ASTM, AISI No. for Name Material Code 1 Unit Outer Casing 304 Stainless AISI 304 Suction Cover Noryl G.F.
  • Page 21 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Sectional View – Z707U Manual Type Output 1/3 HP (Single Phase) Recommended spare parts Part No. Part ASTM, AISI No. for Name Material Code 1 Unit Outer Casing 304 Stainless AISI 304 Suction Cover Noryl G.F.
  • Page 22 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Sectional View – P707U Automatic Type Output 1/3 HP (Single Phase) Recommended spare parts Part No. Part ASTM, AISI No. for Name Material Code 1 Unit Outer Casing 304 Stainless AISI 304 Suction Cover Noryl G.F.
  • Page 23 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Sectional View – P707U Manual Type Output to 1 HP (Three Phase) Recommended spare parts Part No. Part ASTM, AISI No. for Name Material Code 1 Unit Outer Casing 304 Stainless AISI 304...
  • Page 24 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Sectional View – P707U Manual Type Output HP (Three Phase) Recommended spare parts Part No. Part ASTM, AISI No. for Name Material Code 1 Unit Outer Casing 304 Stainless AISI 304 Inner Casing...
  • Page 25 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Sectional View – P707U Manual Type Output 1/3 HP (Single Phase) Recommended spare parts Part No. Part ASTM, AISI No. for Name Material Code 1 Unit Outer Casing 304 Stainless AISI 304...
  • Page 26 CALL 1-800-577-8111 FOR SALES AND SUPPORT EPD, EPPD Disassembly and Assembly 1. Disassembly When disassembling pump, have a piece of cardboard or wooden board ready to place the different parts on as you work. Do not pile parts on top of each other. They should be laid out neatly in rows.
  • Page 27 Warranty COMMERCIAL PUMP/ PRODUCTS LIMITED WARRANTY Ebara International Corporation, Rock Hill, SC (“EIC-RH”) warrants to the original purchaser only (“Customer”) that the EIC-RH Commercial Pump/Product (“Pump”) will be free of defects in workmanship and material for a period of twelve (12) months from the date of...
  • Page 28 CALL 1-800-577-8111 FOR SALES AND SUPPORT Contact your dealer or supplier for more information about other Ebara products: CALL 1-800-577-8111 FOR SALES AND SUPPORT...

This manual is also suitable for:

Eppd