4. Installation

Be sure to take the following cautions and instructions into account when
installing the pump.

4.1 Movement and Fixation

4.1.1 Location

This pump is designed for indoor installation. To install the pump, select a
place with little exposure to dust and humidity and not subject to dew
condensation. Also allow for sufficient space to ensure easy pump
installation and disassembly for maintenance.
In case of installing interface box to the pump, the distance between pump
and interface box shall be 3m or less.
CAUTION Install pump in a location at an ambient not exceeding 30°C.
CAUTION A gap of at least 50mm should be left open for ventilation

4.1.2 Caster and adjustment foot

Four integral mobile support units consisting of a caster and a
height-adjustment foot each are provided underneath the pump base. To
move the pump, raise the four adjustment feet by turning the holding nuts in
the counterclockwise direction.
PM10U
Particular caution is required when the pump is operated in
an enclosed room.
between the pump cover and the adjacent equipment.
Approx.
15 mm
Fig. 4.1 Caster
Caster
Height-adjustment foot