(8) Checking the sense of pump motor rotation.
Look through the sight glass for monitoring the rotation of the pump motor to
check the direction of rotation. The sense of rotation is correct when the
motor rotates in the direction of arrow(counterclockwise direction as seen
from the motor side). When the motor rotates in the reverse direction, please
check the power supply wiring.
When the pump has a vacuum gauge on the suction side, you can also
check the sense of motor rotation from this gauge. If the motor rotates in the
correct direction, the pressure will drop while the pump is being operated.
(9) Check for correct pump operation by turning the start switch on and off a few
times.
CAUTION To check the direction of motor rotation, allow pump to run for

7.2 START/STOP

DIP switches can be set at any time to select the LOCAL / REMOTE /
COMMUNICATION modes and BUZZER Enabled function. Set in accordance
with the operating conditions. (See 6.3. Setting the operational mode.)
WARNING The pump will remain at a very high temperature even after it has
WARNING
CAUTION When the production process leads to react by-products in the
PM10U
about 1 second.
been stopped. Be sure therefore to leave the cooling water on for
about one(1) hour after the pump has been stopped. When the
cooling water is stopped at once after the pump stops, pressure in
the cooling water piping rises. And there is a possibility to cause the
water leak.
The pump and exhaust piping will remain at a high
temperature during operation and for a short time after the
pump has stopped. Be sure to avoid contact and keep
inflammable substances out of reach.
Do not remove the outer cover during operation.
pump or when the process handles corrosive gases, be sure
not to stop the pump until after at least 30 minutes of stopping
the process gases.
P.49