6. Software Control – Lightware Device Controller
6.11. Control Menu
6.11.1. RS-232 Tab
RS-232 data transmission runs three different
P1, P1 channels are for bidirectional RS-232 communication. Disconnected, Control and Command
Injection operation modes are available.
P2, P3 channels can be TTL serial ports or Infra ports depending on the transmitted data protocol.
This port is able to transmit a unidirectional data flow, for example forwarding the serial messages or
Infra messages, which come from the Control Ethernet port (in this case the operation mode is always
Command Injection). Sending serial or infra message is also possible.
TPS channels* are able to send and receive serial data, so P4-P10 ports can operate in Disconnected,
Control and Command Injection mode.
*In MMX8x4-HT400MC and MMX8x4-HT420M models.
The following settings and functions are also available:
Baud rate: 4800, 7200, 9600, 14400, 19200, 38400, 57600, 115200;
Data bits: 8 or 9;
Parity: None, Odd, or Even;
Stop bits: 1, 1.5, or 2;
RS-232 Tab in Control menu
interface:
#rs-232  #rs232 #commandinjection
Applied firmware package: v1.3.0 | LDC software: v2.4.2
MMX8x4-HT series – User's Manual
Command injection port number;
Control protocol: LW2 or LW3;  
Message
sending
Reloading factory defaults (see the
RS-232 Message Sending
The message in the field can be sent out via the
current RS-232 port. Response cannot be seen in
the surface.
ATTENTION!

The escaping is done automatically when sending a message via this surface. When the
message is an LW3 command, it has to be closed by Carriage return and Line feed, e.g.: CALL /MEDIA/
VIDEO/XP:switch(I1:O1)\x0d\x0a.
RS-232 Message Recognizer
This tool can be used to recognize messages coming
from the RS-232 port. The message can be used as a
Condition in Event manager and define an Action for it.
Definitions
Delimiter sequence (hex): Each message is closed by this
separator (if defined).
Accept timeout (ms): When the set time is elapsed after the
last received message and delimiter was not detected,
the device saves the data into the Text, Hex, and Hash
properties. The timeout setting is useful if there is no
special or easily defined delimiter in the incoming data,
but there is a time gap between the messages.
Text: The recognized message in ASCII-format.
Hex: The recognized message in hex format.
Hash: Binary data that is mapped from the original
message. The length of the hash is shorter, and the same
message results the same hash.
Working Method
A message got recognized from the incoming data, if one
of the following occurs:
The set DelimiterHex is detected in the message, or
The set TimeOut has been elapsed since receiving the last data bit.
#protocol
#message
Factory Default Settings
section).
76