8. LW3 Programmers' Reference
8.10.7. Audio Scenes
8.10.7.1. Change the Scene Name
Command and Response
SET·/PRESETS/MICADDON/SCENES/<scene_id>.Name=<scene_name>
ç
pw·/PRESETS/MICADDON/SCENES/<scene_id>.Name=<scene_name>
æ
Parameters
Identifier
Parameter description
<scene_id>
Memory slot identifier
<scene_name>
Name of the scene
Example
ç SET /PRESETS/MICADDON/SCENES/U5.Name=Meeting_room5
æ pw /PRESETS/MICADDON/SCENES/U5.Name=Meeting_room5
8.10.7.2. Save a Scene
Command and Response
ç CALL·/PRESETS/MICADDON/SCENES:saveScene(<index>,I9,I10,I11,O6,<scene_name>)
æ mO·/PRESETS/MICADDON/SCENES:saveScene
Parameters
Identifier
Parameter description
<index>
Memory slot identifier
<scene_name>
Name of the scene
INFO:

I9,I10,I11,O6 are the port numbers of the audio channals which values are saved into a scene. So
these port numbers are always the same.
Example
ç CALL /PRESETS/MICADDON/SCENES:saveScene(5,I9,I10,I11,O6,User 1)
æ mO /PRESETS/MICADDON/SCENES:saveScene
Parameter values
U1-8: It defines which memory slot name will change.
Up to 16 characters are allowed to name a Preset.
Letters (A-Z and a-z), hyphen (-), underscore (_), and
numbers (0-9) are accepted.
Factory default: User 1-8
Parameter values
1-8: It defines which memory slot to save a scene.
Up to 16 characters are allowed to name a scene. Letters
(A-Z and a-z), hyphen (-), underscore (_), and numbers (0-9)
are accepted. Factory default: User 1-8
Applied firmware package: v1.3.0 | LDC software: v2.4.2
MMX8x4-HT series – User's Manual
8.10.7.3. Load a Scene
Command and Response
ç CALL·/PRESETS/MICADDON/SCENES:loadScene(<index>,I9,I10,I11,O6)
æ mO·/PRESETS/MICADDON/SCENES:loadScene
Parameters
Identifier
Parameter description
<index>
Memory slot identifier

INFO:
I9,I10,I11,O6 are the port numbers of the audio channals which values are saved into a scene. So
these port numbers are always the same.
Example
ç CALL /PRESETS/MICADDON/SCENES:loadScene(6,I9,I10,I11,O6)
æ mO /PRESETS/MICADDON/SCENES:loadScene
8.10.7.4. Delete a Scene
Command and Response
ç CALL·/PRESETS/MICADDON/SCENES:deleteScene(<index>)
æ mO·/PRESETS/MICADDON/SCENES:deleteScene
Parameters
Identifier
Parameter description
<index>
Memory slot identifier
Example
ç CALL /PRESETS/MICADDON/SCENES:deleteScene(6)
æ mO /PRESETS/MICADDON/SCENES:deleteScene
Parameter values
1-8: It defines which memory slot to load a scene.
Parameter values
1-8: It defines which
memory slot to delete a
scene.
129