Event Manager Tool Kit; Setting The Delay; Setting The Name Of The Event - Lightware MMX8x4-HT420M User Manual

Multiport matrix switcher
Hide thumbs Also See for MMX8x4-HT420M:
Table of Contents

Advertisement

 
8. LW3 Programmers' Reference
8.22. Event Manager Tool Kit
8.22.1. Setting the Delay
In most cases, the Action is performed immediately after the Condition is detected. But sometimes a delay
is necessary between the Condition and the Action, thus, the following delay options are defined:
no delay
Condition = true
simple delay
Condition = true
still true after
Condition = true
continously
Condition = true
true
Command and Response (summary)
SET·/EVENTS/E<loc>.ConditionTimeout=<time>
ç
pw·/EVENTS/E<loc>.ConditionTimeout=<time>
æ
SET·/EVENTS/E<loc>.ConditionEndCheck=<true/false>
ç
pw·/EVENTS/E<loc>.ConditionEndCheck=<true/false>
æ
SET·/EVENTS/E<loc>.ConditionTimeoutContinuous=<true/false>
ç
pw·/EVENTS/E<loc>.ConditionTimeoutContinuous=<true/false>
æ
Parameters
The
<time>
parameter means seconds. Set the following properties for the desired delay type:
Delay type
Properties to set
no delay
/EVENTS/E<loc>.ConditionTimeout
simple delay
/EVENTS/E<loc>.ConditionTimeout
/EVENTS/E<loc>.ConditionTimeout
still true after
/EVENTS/E<loc>.ConditionEndCheck
/EVENTS/E<loc>.ConditionTimeout
continuously
true
/EVENTS/E<loc>.ConditionEndCheck
/EVENTS/E<loc>.ConditionTimeoutContinuous
Perform the action
Delay
Perform the action
Delay
Condition = true Perform the action
Perform the action
Delay
Time
Value
0
The Action will be lanuched
after the Condition is detected.
<time>
If the Condition is detected, the
action will be launched after the
set time.
<time>
The Condition is fulfilled only
if is detected after the set time
true
again.
<time>
The Condition is fulfilled only if
it is existing continuously during
true
the set time.
true
MMX8x4-HT series – User's Manual
Example 1 (simple delay)
ç SET /EVENTS/E1.ConditionTimeout=10
æ pw /EVENTS/E1.ConditionTimeout=10
If the Condition is detected (the ConditionDetect property becomes true), the ConditionTimeoutPending property
becomes true. 10 seconds later the ConditionTimeoutPending property becomes false and the set Action is
launched.
Example 2 ('still true after' delay type)
ç SET /EVENTS/E1.ConditionTimeout=10
æ pw /EVENTS/E1.ConditionTimeout=10
ç SET /EVENTS/E1.ConditionTimeoutPending=true
æ pw /EVENTS/E1.ConditionTimeoutPending=true
If the Condition is detected (the ConditionDetect property becomes true) the ConditionTimeoutPending property
becomes true. 10 seconds later the Condition is checked again (the ConditionTimeoutPending property
becomes false). If the Condition can be detected again (the ConditionDetect property becomes true again), the
Condition is fulfilled and the set Action is launched.
Example 3 ('continuously true' delay type)
ç SET /EVENTS/E1.ConditionTimeout=10
æ pw /EVENTS/E1.ConditionTimeout=10
ç SET /EVENTS/E1.ConditionTimeoutContinuous=true
æ pw /EVENTS/E1.ConditionTimeoutContinuous=true
If the Condition is detected (the ConditionDetect property becomes true), the ConditionTimeoutPending property
becomes true. If the Condition can be detected in the following 10 seconds continuously (the ConditionDetect
property stays true), the Condition is fulfilled, the ConditionTimeoutPending property becomes false, and the set
Result
Action is launched.
8.22.2. Setting the Name of the Event
Command and Response
SET·/EVENTS/E<loc>.Name=<string>
ç
pw·/EVENTS/E<loc>.Name=<string>
æ
Parameters
The
<string>
( _ ), and space ( ) up to 20 characters. Longer string results an error, unaccepted characters are skipped.
Example
ç SET /EVENTS/E1.Name=Projector_ON
æ pw /EVENTS/E1.Name=Projector_ON
Applied firmware package: v1.3.0 | LDC software: v2.4.2
may contain letters (A-Z) and (a-z), numbers (0-9), special characters: hyphen ( - ), underscore
146

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mmx8x4-ht400mcMmx8x8-hdmi-4k-aMmx8x8-hdmi-4k-a-usb20

Table of Contents