8. LW3 Programmers' Reference
8.13.9. Set the Active Timeout
This property is responsible for clearing the ActiveRx, ActiveRxHex, ActiveHash properties after the elapsed
time. Default value is 50ms.
Command and Response
SET·/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=<a_timeout>
ç
pw·/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=<a_timeout>
æ
Parameters
The
<a_timeout>
parameter is the active timeout value (ms) between 0 and 255.
Example
ç SET /MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=255
æ pw /MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=255
8.13.10. Running an Immediate Event Action
DIFFERENCE:

This command is available from firmware v1.6.0.
When a message is recognized (DelimiterHex is detected in the message, or TimeOut has been elapsed
since receiving the last data bit) a specific Action of an Event can be run by the following command.
Command and Response
SET·/MEDIA/UART/RECOGNIZER.ActionTrigger=<event_nr>
ç
pw·/MEDIA/UART/RECOGNIZER.ActionTrigger=<event_nr>
æ
Parameters
The
<event_nr>
means the number (location) of the linked Event Action without letter 'E'. (There is no need
to define a Condition in the linked Event.)
Example
ç SET /MEDIA/UART/RECOGNIZER.ActionTrigger=5
æ pw /MEDIA/UART/RECOGNIZER.ActionTrigger=5
MMX8x4-HT series – User's Manual
8.14. IR Port Configuration
8.14.1. Enable the IR Port
Command and Response
SET·/MEDIA/IR/<ir_port>.Enable=<ir_port_staus>
ç
pw·/MEDIA/IR/<ir_port>.Enable=<ir_port_staus>
æ
Parameters
Identifier
<ir_port>
<ir_port_staus>
* The number of the ports depends on the model type. The exact port numbering is listed in
section.
Example
ç SET /MEDIA/IR/D1.Enable=true
æ pw /MEDIA/IR/D1.Enable=true
8.14.2. Query the IR Command Injection Port Number
Command and Response
ç GET·/MEDIA/IR/<ir_port>.CommandInjectionPort
æ pw·/MEDIA/IR/<ir_port>.CommandInjectionPort
Example
ç GET /MEDIA/IR/D1.CommandInjectionPort
æ pw /MEDIA/IR/D1.CommandInjectionPort
Applied firmware package: v1.3.0 | LDC software: v2.4.2
#ir #infrared