8. LW3 Programmers' Reference
8.22.3. Enable the Event
Command and Response
SET·/EVENTS/E<loc>.Enabled=<true/false>
ç
pw·/EVENTS/E<loc>.Enabled=<true/false>
æ
Parameters
When the property value is true (or 1), the Action will be launched if the Condition is detected. If the property
is false (or 0), the Action will not run, however, the Condition counter will be increased when detected.
Example
ç SET /EVENTS/E1.Enabled=true
æ pw /EVENTS/E1.Enabled=true
8.22.4. Triggering a Condition
DIFFERENCE:

This command is available from FW package v1.3.0.
This feature works like a condition is fulfilled. When a complex control system is built, a Condition may
trigger numerous Actions. A typical example is when a system is powered on and the 'ready-to-use' state
has to be loaded. In this case, there could be many actions which are based on the same condition. In order
to reduce the number of the commands, you can trigger one 'key' condition, which starts the whole process.
Command and Response
ç CALL·/EVENTS/E<loc>:triggerCondition(1)
æ mO·/EVENTS/E<loc>:triggerCondition
Example
ç CALL /EVENTS/E1:triggerCondition(1)
æ mo /EVENTS/E1:triggerCondition
The Condition of Event1 is fulfilled, the set Action will be launched (after the delay if set).
8.22.5. Querying the Condition Counter
This property shows how many times the Condition has been detected and triggered altogether. The counter
is reset at boot.
Command and Response
ç GET·/EVENTS/E<loc>.ConditionCount
pw·/EVENTS/E<loc>.ConditionCount=<num_value>
æ
Example
ç GET /EVENTS/E1.ConditionCount
æ pw /EVENTS/E1>.ConditionCount=5
MMX8x4-HT series – User's Manual
8.22.6. Querying the Condition Trigger Counter
DIFFERENCE:

This property shows how many times the Condition has been triggered but does not contain the number of
real detections. The counter is reset at boot.
Command and Response
ç GET·/EVENTS/E<loc>.ExternalConditionTriggerCount
pw·/EVENTS/E<loc>.ExternalConditionTriggerCount=<num_value>
æ
Example
ç GET /EVENTS/E1.ExternalConditionTriggerCount
æ pw /EVENTS/E1.ExternalConditionTriggerCount=2
8.22.7. Testing an Action
This tool is for launching the Action without detecting or triggering the Condition.
Command and Response
ç CALL·/EVENTS/E<loc>:ActionTest(1)
æ mO·/EVENTS/E<loc>:ActionTest
Example
ç CALL /EVENTS/E1:ActionTest(1)
æ mO /EVENTS/E1:ActionTest
Applied firmware package: v1.3.0 | LDC software: v2.4.2