8. LW3 Programmers' Reference
8.7.17. Changing the Input Port Priority
This method required escaping the control characters. For more information see the
input can be set in the same time.
Command and Response
ç CALL·/MEDIA/VIDEO/XP:setAutoselectionPriority(<in>\(<out>\):<prio>);(<in>\(<out>\):<prio>)
æ mO·/MEDIA/VIDEO/XP:setAutoselectionPrioirty
Parameters
The
<prio>
parameter is the riority number from 0 to 31. Equal numbers are allowed (31 means that the port
will be skipped from the priority list). An input port priority can be set on an output port. Many settings can
be executed by separating a semicolon (no space), see the example below.
Example
ç CALL /MEDIA/VIDEO/
XP:setAutoselectionPriority(I1(O1):31;I2(O1):1;I3(O1):2;I4(O1):3;5(O1):4;I6(O1):5;I7(O1):6;I8(O1):7)
æ mO /MEDIA/VIDEO/XP:setAutoselectionPriority
The Input 1 is ignored from the autoselection, priority order of the inputs are: I2, I3, I4, I5, I6, I7, I8.
8.7.18. PoE Enable

INFO:
This command is available in MMX8x4-HT420M model.
Command and Response
SET·/REMOTE/<tps_port>.PoeEnabled=<poe_status>
ç
pw·/REMOTE/<tps_port>.PoeEnabled=<poe_status>
æ
Parameters
Identifier
Parameter description
<tps_port>
TPS port number
<poe_status>
PoE status
* TPS output ports are not available in MMX8x4-HT400MC model.
Example
ç SET /REMOTE/S2.PoeEnabled=true
æ pw /REMOTE/S2.PoeEnabled=true
Escaping
section. One or more
Parameter values
S1-S4 for inputs
D1-D2* for outputs
true: PoE enabled
false: PoE disabled
Applied firmware package: v1.3.0 | LDC software: v2.4.2
MMX8x4-HT series – User's Manual
8.7.19. TPS Mode Settings on TPS Ports

INFO:
This command is available in MMX8x4-HT400MC and MMX8x4-HT420M models.
Command and
Response #tpsmode
SET·/REMOTE/<tps_port>.tpsModeSetting=<tps_mode_setting>
ç
pw·/REMOTE/<tps_port>.tpsModeSetting=<tps_mode_setting>
æ
Example
ç SET /REMOTE/S2.tpsModeSetting=A
æ pw /REMOTE/S2.tpsModeSetting=A
Parameters
Identifier
<tps_port>
<tps_mode_setting>
* TPS output ports are not available in MMX8x4-HT400MC model.
** Long reach and LPPF2 mode is not available in MMX8x4-HT400MC model.
For more information see the
8.7.20. Signal Type Settings (Output Ports)
Command and Response
#signaltype
SET·/MEDIA/VIDEO/<out>.HdmiModeSetting=<signal_type>
ç
pw·/MEDIA/VIDEO/<out>.HdmiModeSetting=<signal_type>
æ
Example
ç SET /MEDIA/VIDEO/O1.HdcpModeSetting=1
æ pw /MEDIA/VIDEO/O1.HdcpModeSetting=1
Parameters
<signal_type>
Signal type
Parameter description
Parameter values
TPS input or output port S1-S4 for inputs
D1-D2* for outputs
TPS mode
A: Auto
H: HDBaseT
L**: Longreach
1: LPPF1
2**: LPPF2
TPS Interface
section.
0: Auto; 1: DVI; 2: HDMI