3.3.2. Connecting Power

l Refer to "2.12. TB: Terminal Block for Power Supply" for more details.
l Provide anti-heat vinyl AWG16 cables for the power supply cable.
l Do not place the main power AC line cable and the signal wires in close proximity. Do not
bundle up them and not put in the same duct.
l Install a noise filter between the power source and the Driver Unit to protect the System from the
external noises.
Table 3-3: Noise filter requirement [Recommended manufacturer: Schaffner]
Power source
Single phase
100VAC, 200VAC
l Separate the wiring s of the primary and the secondary noise filters, and take different routing.
l The Driver Unit and the noise filter shall be close to each other.
l Be sure to install the surge killer circuit to the coils of magnetic switch, relay and solenoid.
l An inrush current flows when the power is turned on because the capacitive load is connected to
the main power supply circuit. For this reason, use the contacts, if necessary, such as magnetic
switch that have higher rated current as shown below.
Table 3-4
Non-fuse breaker
Short circuit breaker
Magnetic switch
Table 3-5: Inrush current
Item
Control power
Main power
! Caution: Do not lose the screws for the terminal when wiring the Terminal block.
l Refer to Figure 3-5 for wiring the power.
Type
FN2070-40
Contacts
10 A
10 A, Sensitivity: 15 mA
10 A
Inrush current (Typical)
Power supply
100 VAC
7.5 A
10 A
Rated voltage
250 VAC
Rated current
Power supply
200 VAC
15 A
20 A
— 3-5 —
3.3. Wiring
3.3.2. Connecting Power
Rated current
AC10A
Time
10 msec
10 msec