6.4.2.1. Dead Band Set to Command Voltage

l You may set dead band to the analog command voltage.
(Parameter DBA: ± 4.9mVper parameter data.)
Figure 6-32: Example: DBA100 (AC1)
- 10 V
- 490 mV
CCW
Max. torque

6.4.2.2. Offsetting Analog Command

l You may adjust offset value of command voltage with the parameter AF.
l Offset adjustment of the Driver Unit has been made at the shipping. With the parameter AF,
reset the offset in accordance with the master controller.
l The parameter AF sets the offset value by -4.9 mV per parameter data in the range of AF -63 to
AF 63.
Figure 6-33: Example: AF10 (AC1)
- 10 V
- 49 mV
CCW
Max. torque
(1) Automatic offset setting
l Set the offset value automatically to make the current analog input to 0 (zero).
l Refer to (1) Automatic offset setting in "6.3.2.2.Offsetting Analog Command."
(2) Manual offset setting
l Adjust offsetting manually with the analog command monitor.
l Refer to (2) Manual offset setting in "6.3.2.2. Offsetting Analog Command."
CW
Max. torque
+ 490 mV
+ 10V
CW
Max. torque
+ 10 V
— 6-39 —
6.4. Torque Control Mode Opeation
6.4.2. Analog Command Operation