CO : Position Error Counter Over Limit

Format
Data
Shipping set
Default
l The CO sets the threshold for "Excess position error" alarm.
l When the position error exceeds the set value, the Driver Unit outputs the excess position error
alarm and opens the DRDY output circuit.
l The TS or ?CO command reports the current setting.
«

CR : Circular Resolution

Format
Data
Shipping set
Default
l Use the CR to specify the resolution of pulse train input.
l For the details, refer to "6.2.3. Pulse Train Command Positioning Operation."
l The resolution changes immediately after the CR data command is entered.
l The TS or ?CR command reports the current setting.
CS : Acceleration Pattern Select (common setting)
Format
Data range
Shipping set
Default
l The CS command selects a pattern of the acceleration profiling.
l data1 sets an accelerating pattern while data2 sets a deceleration pattern.
l When data2 is default, the pattern of data1 shall be applied to data2.
l The TS or ?CS command reports the current setting.
: CO data
: 1 to 99 999 999 [pulse]
: 50 000
: Not available
: CR data
: X1, X2, X4, 360 000, 36 000, and 3 600
: X1
: Not available
: CS data1, data2
: 1 to 5
: 1,1
: Not available
1: Constant acceleration
2: Modified sine
3: Modified trapezoid
4: Cycloid
5: Half sine