7.1.18.7. Monitoring Torque Command and Software Thermal Loading

l The command TT monitors torque command and thermal loading.
l This is useful to check a margin of generating torque, and the state of thermal loading in the
continuous operation.
Figure 7-27: Monitoring example (TT/RP)
Torque command:
Maximum torque command index: ± 511
Phase A, B or C that has the
highest thermal loading

7.1.18.8. Monitoring State of Automatic Gain Switching

l The TG command monitors the state in the automatic gain switching function.
Figure 7-28: Monitoring example (TG/RP)
Gain presently applied
'U': VG • VI
'L': VGL• VIL
'*': No gain applied.
Existence of position
command
'#': Exists.
'*': No command
Data of error counter [pulse]
à Input format
TT/RP
/RP default : Reads out only once.
/RP attached : Real time readout
à Press the BS key to terminate the real time monitoring (TT/RP).
:TT/RP
A16384/32767, 50.0
Thermal loading index
à Input format
TG/RP
/RP default : One shot monitoring.
/RP attached : Real time monitoring.
à Press the BS key to terminate the real time monitoring (TG/RP).
à Refer to "7.2.7. Automatic Gain Switching" for more details.
:TG/RP
U,#,
1200, 600
7.1.18. Monitoring via RS-232C Communication
383,
75.0
Allowable thermal loading index
Remaining time to make gain
change for stopping. [ms]
— 7-33 —
7.1. General Operation and Function
Percent of current torque command
against the maximum torque [%]
Percent of current thermal loading:
Overload at 100 [%].
(Alarm of A3 > Overload will
occur.)