7.1. General Operation and Function
7.1.18. Monitoring via RS-232C Communication
7.1.18.12. Monitoring Histories of Program Execution and Changes on Control I/O
l The DP command monitors executing history of a program and history of changes on the control
Inputs and Outputs.
l The System stores the history of starts, completions and interruptions of a channel program, and
history of changes on control Input/Output in the order of occurrence. The maximum store
capacity is sixty-four histories.
l This function can be used for checking the programs of the host controller.
Figure 7-32: Monitoring example (DP)
Figure 7-33: Format for monitors of control Input/Output
Figure 7-34: History readout of program execution
à Input format: DP
à When the parameter MM is set to MM1, the prompt ";" appears on the end of history
readout and the System waits for the next key entry. Pressing the SP key reads out
history that goes one step in the past. Every one press of the R key monitors a
current history of execution. The BS key terminates the monitoring.
à When the parameter MM is set to MM0, the System monitors all histories together,
and then gets out the monitoring. This function is for checking histories with a personal
computer.
:DP
CH15,STA;
10000001(15)00/10;
10000000(15)00/10;
0 0 0 0 0 0 0 0 ( 0 0 ) 0 0 / 0 0
CH**,STA
Program state :STA ... Start
Channel number
History of program execution.
Change history of control
Input/Output
Signal name
OVER
DRDY
INH
STP
PRG0 to 5
(10 decimal)
RUN
JOG
OTP
OTM
CLR
HOS
EMST
SVON
:FIN ... Completion
:ABO ... Interruption
— 7-36 —
B
B
3
3
t
t
y
y
p
p
e
e
B
B
5
5
t
t
y
y
p
p
e
e
2
3
t
y
p
e
2
5
t
y
p
e
2
3
t
y
p
e
2
5
t
y
p
e

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents