u Abnormal Main AC Line Voltage (Excessive voltage/Low voltage): P1
(1) Abnormal power supply voltage.
(2) à Main circuit voltage is excessive due to
high acceleration/deceleration under heavy
load inertia.
à The voltage of the input power of the
power amplifier exceeds 250 VAC due to
error in the power supply.
(3) The voltage of the power amplifier main
circuit lowers below 70 VAC.
(4) Blown fuse.
(Motor over temperature, error in power
supply wiring, Driver Unit abnormal.)
(5) Excessive regeneration voltage.
(6) Defective PCB.
(When the alarm is on after the Motor stops
even power source and fuse are normal.)
Note: 1) When the regeneration dump resistor cannot process regenerative current, the voltage
2) Decrease acceleration/deceleration.
u Over Current: P2
(1) Poor insulation of the Motor. (Refer to
"Appendix 2. How to Check Motor
Condition.")
(2) Defective Motor Cable. (Refer to "Appendix
2. How to Check Motor Condition.")
(3) Defective FET of Power Amplifier. (When
the alarm is on even the Motor and Motor
cable are normal.)
l The alarm may be accompanied by "Abnormal main AC line voltage (blown fuse)" alarm due
to excessive current flow.
u Control AC Line Under Voltage: P3
(1) Low voltage of control power input.
(2) Control circuit voltage for the power
amplifier falls below 70VAC due to inferior
power supply.
(3) Defective PCB.
(When the alarm is on after control power
is turned on.)
Cause
of direct current to main circuit will be too high, and, eventually, the alarm will be on.
Cause
Cause
— 10-9 —
10.3. Cause and Remedy of Alarm
Remedy
· Check the main power supply.
(Excessive voltage, low voltage and power source
capacity.)
· Check fuse, power source and the cable, and then
turn power on again.
· Refer to "Appendix 4. How to Replace ESB Driver
Unit."
· Readjust operation duty; reduce the load, and
acceleration/deceleration.
· Refer to "Appendix 4. How to Replace ESB Driver
Unit."
Remedy
· Replace the Motor.
· Replace the Cable.
· Refer to "Appendix 4. How to Replace ESB Driver
Unit."
Remedy
· Check the control power voltage.
(Low voltage due to over current or output shorting.)
· Turn off power, check the power supply and power
cable, and then turn on power again.
· Refer to "Appendix 4. How to Replace ESB Driver
Unit."