6.3.2.1. Dead Band Set to Command Voltage

l You may set a dead band to the analog command.
(The parameter DBA sets ± 4.9mV per parameter data.)
Figure 6-27: Example: DBA100 (AC1)
-10 V
- 490 mV

6.3.2.2. Offsetting Analog Command

l You may adjust offset value of command voltage with the parameter AF.
l Parameter AF sets the offset value by "– 4.9 mV" per parameter data in the range of AF -63 to
AF63.
Figure 6-25: Example: Setting AF10 (AC1 )
- 10 V
- 49 mV
-1
3 s
+ 490 mV
+ 10 V
-1
-3 s
-1
3 s
+ 10 V
-1
- 3 s
— 6-33 —
6.3. Velocity Contorl Mode Operation
6.3.2. Analog Command Operation