Parameter
6.6.2

Jog operation (Pr. 15, Pr. 16)

Jog operation is used to setup the machine.The frequency and acceleration/deceleration time for Jog
operation can be set. As soon as the frequency inverter receives the start signal, the motor is accel-
erated at the frequency entered in parameter 15 (jog frequency) using the preset acceleration/brake
time (parameter 16). Jog operation can be performed in either of the external and the PU operation
mode.
Pr. No. Name
Initial Value
15
Jog frequency
Jog acceleration/
16
deceleration time
These parameters are displayed as simple mode parameter only when the parameter unit (FR-PU04/
FR-PU07) is connected. When the parameter unit is not connected, the above parameters can be set
when Pr. 160 "User group read selection" = 0.
Jog operation from outside
When the jog signal is on, a start and stop can be made by the start signal (STF, STR). For the terminal
used for Jog operation selection, set "5" in any of Pr. 178 to Pr. 184 "Input terminal function selection"
to assign the function.
Fig. 6-20: Connection diagram for external jog operation
FR-E700 SC EC/ENE
Setting Range
Description
5 Hz
0–400 Hz
Set the frequency for jog operation.
Acceleration/deceleration time for jog operation.
This setting is related to to the reference frequency set
in Pr. 20 and the increments set in Pr. 21.
Pr. 21 = 0 (Initial setting)
Setting range: 0–3600 s
0.5 s
0–3600/360 s
Increments: 0.1s
Pr. 21 = 1
Setting range: 0–360 s
Increments: 0.01 s
The acceleration and deceleration times cannot be set
separately.
Power
supply
Forward rotation start
Reverse rotation start
Jog operation
Frequency setting by external terminals
Parameters referred to
13
29
20
21
79
178–184
Inverter
Motor
When assigning the jog signal to the
terminal RH
Refer to
Section
Starting frequency
6.7.2
Acceleration/
6.7.3
deceleration pattern
selection
Acceleration/
6.7.1
deceleration reference
frequency
Acceleration/
6.7.1
deceleration time
increments
Operation mode
6.18.1
selection
Input terminal
6.10.1
function selection
I001788E