Check And Clear Of The Fault History - Mitsubishi Electric FR-E700 Instruction Manual

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Troubleshooting
7.5

Check and clear of the fault history

Check for the fault history
Fig. 7-5:
The cumulative energization time and actual operation time are accumulated from 0 to 65535
hours, then cleared, and accumulated again from 0. When the operation panel is used, the time
is displayed up to 65.53 (65530 h) in the indication of 1 h = 0.001, and thereafter, it is added up
from 0.
FR-E700 SC EC/ENE
Monitor/frequency setting
Operation panel is used for
operation
Faults history
Flickering
Flickering
Flickering
Displaying the fault list and the status values for the time of the fault
Parameter setting
Parameter setting change
Procedure for displaying the faults history and the status values for the time of the fault
Eight past faults can be displayed with the digital dial.
(The last fault in the list is identified by a dot after the E: "E.")
When no alarm exists
Output frequency
Flickering
Energizing time
Flickering
Fault history number
(The number of past faults is displayed.)
Press
the digital dial.
Press
the digital dial.
Press
the digital dial.
Check and clear of the fault history
is displayed.
Output current
Flickering
Output voltage
Flickering
I001857E
7 - 21