Operation panel
4.3.8

Change the parameter setting value

Example
Change the Pr. 1 "Maximum frequency" setting from 120 Hz to 50 Hz.
Screen at powering on
The monitor display appears.
Press the PU/EXT key to choose the PU
operation mode.
Press the MODE key to choose the parameter
setting mode.
Turn the digital dial until P.1 (Pr. 1) appears.
Press the SET key to show the currently set value.
The initial value "120.0" appears.
Turn the digital dial counter clockwise to change it
to the setting value of "50.00".
Press the SET key to set.
Turn the digital dial to read another parameter.
Press the SET key to show the setting again.
Press the SET key twice to show the next parameter.
Press the MODE key twice to return the monitor to frequency monitor.
Fig. 4-12: Setting the maximum output frequency
Possible faults:
● "Er1" to "Er4" is displayed ... Why?
– The error indication means:
Er1: Write disable error
Er2: Write error during operation
Er3:
Er4:
For details refer to section 7.1.
4 - 16
Operation
Calibration error
Mode designation error
Operation
Display
PU indication is lit.
PRM indication is lit.
The parameter number
read previously appears.
Flicker ... Parameter setting complete!
I001462E