Mitsubishi Electric FR-E700 Instruction Manual page 417

Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter
● Inverter status monitor
Item
Inverter
status
monitor
Inverter
status
monitor
(extended)
Tab. 6-84: Monitoring the inverter status
The signal within parentheses is the initial setting. The description changes depending on the
setting of Pr. 190 to Pr. 192 "Output terminal function selection". (Refer to section 6.10.5.)
FR-E700 SC EC/ENE
Instruction
Bits
Description
Code
b0: RUN (inverter running)
b1: Forward rotation
b2: Reverse rotation
b3: SU (up to frequency)
b4: OL (overload)
H7A
8
b5: —
b6: FU (frequency
detection)
b7: ABC (alarm)
b0: RUN (inverter running)
b1: Forward rotation
b2: Reverse rotation
b3: SU (up to frequency)
b4: OL (overload)
b5: —
b6: FU (frequency
detection)
b7: ABC (alarm)
b8: —
H79
16
b9: —
b10: —
b11: —
b12: —
b13: —
b14: —
b15: Alarm occurrence
Communication operation and setting
Example
Example 1: H02 (During forward rotation)
Example 2: H80 (Stop at alarm occurrence)
Example 1: H0002 (During forward rotation)
Example 2: H8080 (Stop at alarm occurrence)
6 - 263

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents