Communication operation and setting
● Run command
Item
Run
command
Run
command
(extended)
Tab. 6-83: Run commands
The signal within parentheses is the initial setting. The description changes depending on the
setting of Pr. 180 to Pr. 184 "Input terminal function selection". (Refer to section 6.10.1.)
The signal within parentheses is the default setting. Reset cannot be controlled by the network,
bit 11 is invalid in the initial status. When using bit 11, change the signal with Pr. 184 "RES terminal
function selection" (section 6.10.1) (Reset can be executed with the instruction code HFD.)
When Pr. 551 = 2 (PU Mode control source is PU connector), only forward rotation and reverse
rotation can be used.
6 - 262
Instruction
Bits
Description
Code
b0: AU (current input
selection)
b1: Forward rotation start
b2: Reverse rotation start
b3: RL (low speed)
HFA
8
b4: RM (middle speed)
b5: RH (high speed)
b6: RT (second function
selection)
b7: MRS (output stop)
b0: AU (current input
selection)
b1: Forward rotation start
b2: Reverse rotation start
b3: RL (low speed)
b4: RM (middle speed)
b5: RH (high speed)
b6: RT (second function
selection)
b7: MRS (output stop)
HF9
16
b8: —
b9: —
b10: —
b11: RES (reset)
b12: —
b13: —
b14: —
b15: —
Example
Example 1: H02 (Forward rotation)
Example 2: H00 (Stop)
Example 1: H0002 (Forward rotation)
Example 2: H0800 low speed operation
(When Pr. 184 "RES terminal function selection" is set to "0")