Parameter
Setting the operation mode
The following explains a program to write various data to the inverter.
The following explains a program to change the operation mode of station 1 inverter to network
operation.
● Operation mode write code: HFB (hexadecimal)
● Network operation set data: H0000 (hexadecimal) (Refer to page 6-361)
● The reply code (RWr2) at the time of instruction code execution is set to D2.
(For information about the reply code (RWr2) refer to page 6-360.)
SM1536
SD1536.0
SD1540.0
(0)
M0
X20
(4)
M300
(8)
M301
X100F
10)
M302
X100F
19)
25)
Abb. 6-178:
Program example 2
FR-E700 SC EC/ENE
M0
Check the data link status of the station 1
PLS
M300
SET
M301
MOV
H0FB
W102
Write operation mode write code (HFB) to
RWw2 and set data (H0000) to RWw3.
MOV
H0
W103
Turn on the instruction code execution request
SET
Y100F
(RY0F)
RST
M301
SET
M302
Read reply code (RWr2) to D2 when the instruction
code execution completion (RX0F) turns on.
MOV
W2
D2
Turn off the instruction code execution request
RST
Y100F
(RY0F)
RST
M302
END
CC-Link IE Field Network Basic
I003130E
6 - 367