Jog Operation (Pr.15 , Pr.16 ); Run Key Rotation Direction Selection (Pr.17 ) - Mitsubishi Electric FR-S500E Instruction Manual

Frequency inverter
Table of Contents

Advertisement

Explanation of functions (parameters)
2.3.10 Jog operation (Pr.15
To start/stop jog operation in the
external operation mode, choose the
jog operation function in input terminal
function selection, turn on the jog
signal, and turn on/off the start signal
(STF, STR).
You can choose the jog operation
mode from the parameter unit (FR-
PU04) and perform jog operation
using the
FWD
(Can be read as the basic parameters when the FR-PU04 is connected.)
Set the frequency and acceleration/deceleration time for jog operation.
Parameter
Name
15
Jog frequency
Jog acceleration/
16
deceleration time
CAUTION
In S-shaped acceleration/deceleration pattern A, the acceleration/deceleration
time is the period of time required to reach Pr. 3 "base frequency", not Pr. 20
"acceleration/deceleration reference frequency".
The acceleration time and deceleration time cannot be set separately for jog
operation.
The Pr. 15 "Jog frequency" value should be equal to or higher than the Pr. 13
"starting frequency" setting.
Assign the jog signal using any of Pr. 60 to Pr. 63 (input terminal function
selection).
Related parameters
Assignment of jog signal to terminal ⇒ Pr. 60 to Pr. 63 (input terminal function selection)
Acceleration/deceleration pattern S-shaped acceleration/deceleration A
⇒ Pr. 29 "acceleration/deceleration pattern" (refer to page 77)
2.3.11
RUN
RUN
Used to choose the direction of rotation by operating the
panel.
Parameter
Name
RUN key rotation
17
direction selection
Refer to
Refer to
or
.
REV
Factory Setting Setting Range
5Hz
0.5s
(refer to page 96)
key rotation direction selection (Pr.17
Factory
Setting
0
(page 63)
,
(page 65)
, Pr.16
Output frequency (Hz)
Jog frequency
setting range
Pr.15
JOG signal
STF signal
0 to 120Hz
0 to 999s
Setting
Range
0: Forward rotation
0, 1
1: Reverse rotation
72
)
Pr.20
Forward
rotation
Pr.16
ON
ON
Remarks
Setting is enabled when
Pr. 30 = "1".
)
RUN
key of the operation
Remarks
Setting is enabled
when Pr. 30 = "1".

Advertisement

Table of Contents
loading

Table of Contents