Simple mode parameter list
Screen at powering on
The monitor display appears.
Press the PU/EXT key to choose the PU
operation mode.
Press the MODE key to choose the parameter
setting mode.
Turn the digital dial until P.7 (Pr. 7) appears.
Press the SET key to show the currently set value.
The initial value "5.0" appears.
Turn the digital dial to change it to the setting
value of "10.0".
Press the SET key to set.
By turning the digital dial, you can read another parameter.
Press the SET key to show the setting again.
Press the SET key twice to show the next parameter.
Fig. 5-8:
5 - 10
Operation
Setting the acceleration time
Basic settings
Display
PU indication is lit.
PRM indication is lit.
The parameter number read previously
appears.
The initial value differs
according to the
capacity.
Flicker ... Parameter setting complete!