Parameter
Ethernet function selection (Pr. 833 to Pr. 835)
Refer to the Instruction Manual of the device connected via Ethernet, and set Pr. 833 to Pr. 835 Ether-
net function selection1 to 3 according to the application and protocol.
A communication socket is provided only for the selected application.
Pr.833 to Pr.835 setting
0
10
20 (Pr. 834 initial value)
30
31 (Pr. 833 initial value)
36
38
9999 (Pr. 835 initial value) Unselected
Tab. 6-108: Settings for the Ethernet function selection
If both application and protocol settings are identical in Pr.833 to Pr.835, the priority of the set-
ting is defined as follows: Pr. 833 > Pr. 834 > Pr. 835.
(Example) When Pr. 833 = "31", Pr. 834 = "36", Pr. 835 = "20", "20" and "31" are valid.
To establish the Ethernet communication between the inverter and FR Configurator2, set "20" and
"31" in any two of Pr. 833 to Pr. 835.
Communication speed and full-duplex/half-duplex selection (Pr.832)
Set the communication speed and the communication mode (full-duplex/half-duplex) in Pr. 832 Link
speed and duplex mode selection. If the operation is not performed properly in the initial setting
(Pr. 832 = "0"), set Pr. 832 according to the specifications of the connected hub.
Pr. 832
0 (initial value)
1
2
3
4
Tab. 6-109: Setting of Pr. 832
FR-E700 SC EC/ENE
Port
Application
number
502
MODBUS®/TCP
61450
CC-Link IE Field Network Basic
45237
iQSS (supported by FR Configurator2)
5000
5001
MELSOFT / FA product connection
5006
5008
Communication
Full-duplex/
speed
halfduplex system
Automatic negotiation
Automatic negotiation
100 Mbps
Full-duplex
100 Mbps
Half-duplex
10 Mbps
Full-duplex
10 Mbps
Half-duplex
Communication operation and setting
Number of con-
Protocol
nectable clients
TCP/IP
3
UDP/IP
No limit
UDP/IP
No limit
UDP/IP
No limit
UDP/IP
No limit
UDP/IP
No limit
UDP/IP
No limit
Remarks
The communication speed and the communication
mode (half-duplex/full-duplex) are automatically
negotiated to ensure the optimum setting.
Refer to
page
6-333
6-349
6-291
6 - 285