Misoperation prevention and parameter setting restriction
6.17.4

User groups (Pr. 160, Pr. 172 to Pr. 174)

Parameter which can be read from the operation panel and parameter unit can be restricted. In the in-
itial setting, only the simple mode parameters are displayed.
Pr. No. Name
160
User group read selection
User group registered display/batch
172
clear
173
User group registration
174
User group clear
The above parameter can be set when Pr. 160 "User group read selection" = 0.
The values read from Pr. 173 and Pr. 174 are always "9999".
This parameter allows its setting to be changed during operation in any operation mode even if
"0" (initial value) is set in Pr. 77 "Parameter write selection".
Display of simple mode parameters and extended parameters (Pr. 160)
When Pr. 160 = "9999", only the simple mode parameters can be displayed on the operation panel and
parameter unit (FR-PU04/FR-PU07). (Refer to the parameter list Tab. 6-1 for the simple mode param-
eters.)
Setting "0" to Pr. 160 enables the display of the simple mode parameters and extended parameters.
NOTES
When a plug-in option is fitted to the inverter, the option parameters can also be read.
When reading the parameters using the communication option, all parameters (simple mode,
extended mode, parameters for options) can be read regardless of the Pr. 160 setting.
When RS-485 communication is used to read the parameters, all parameters can be read, regard-
less of the Pr. 550 "NET mode operation command source selection", Pr. 551 "PU mode operation
command source selection", regardless of Pr. 160 setting.
(auto-detect)
(initial value)
Pr. 15 "Jog frequency", Pr. 16 "Jog acceleration/deceleration time", and Pr. 991 "PU contrast adjust-
ment" are displayed as simple mode parameter when the parameter unit (FR-PU04/FR-PU07) is
fitted.
6 - 198
Setting
Initial Value
Description
Range
9999
Only the simple mode parameters can be displayed.
The simple mode and extended parameters can be
0
0
displayed.
Only parameters registered in the user group can be
1
displayed.
Displays the number of cases registered as a user
(0–16)
group (Read only)
0
9999
Batch clear the user group registration
0–999/
Set the parameter numbers to be
9999
9999
registered to the user group.
0–999/
Set the parameter numbers to be cleared from the
9999
9999
user group.
Pr. 551
2 (PU)
0 (communication option)
3 (USB)
9999
9999 (auto-detect)
Pr. 550
2 (PU)
(initial value)
Parameters referred to
550
NET mode operation
command source
selection
551
PU mode operation
command source
selection
Pr. 160 Valid/Invalid
Valid
Valid
Invalid (all readable)
With communication option: valid
Without communication option: invalid
(all readable)
Parameter
Refer to
Section
6.18.3
6.18.3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents