Jog Operation (Pr. 15, Pr. 16) - Mitsubishi Electric FR-E720-008 Instruction Manual

Hide thumbs Also See for FR-E720-008:
Table of Contents

Advertisement

4.7.2

Jog operation (Pr. 15, Pr. 16)

You can set the frequency and acceleration/deceleration time for Jog operation. Jog operation can be performed in either
of the External and the PU operation mode.
This operation can be used for conveyor positioning, test operation, etc.
Parameter
Name
Number
15
Jog frequency
Jog acceleration/
16
deceleration time
These parameters are displayed as simple mode parameter only when the parameter unit (FR-PU04/FR-PU07) is connected. When the parameter unit is not
connected, the above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 187)
∗ When the Pr. 21 Acceleration/deceleration time increments setting is "0" (initial value), the setting range is "0 to 3600s" and setting increments is "0.1s". When
the setting is "1", the setting range is "0 to 360s" and the setting increments is "0.01s".
(1)
Jog operation from outside
When the JOG signal is ON, a start and stop can be made by the start signal (STF, STR).
For the terminal used for Jog operation selection, set "5" in any of Pr.178 to Pr.184 (input terminal function selection) to assign
the function.
Output frequency (Hz)
Pr. 20
Pr. 15 Jog frequency
Forward
rotation
setting range
Pr. 16
JOG signal
Forward rotation STF
ON
Reverse rotation STR
Operation
1.
Screen at powering ON
Confirm that the External operation mode is
selected. ([EXT] lit)
If not displayed, press
External (EXT) operation mode. If the
operation mode still does not change, set Pr.
79 to change to the External operation mode.
2.
Turn ON the JOG switch.
3.
Turn the start switch (STF or STR) ON.
The motor runs while the start switch (STF
or STR) is ON.
The motor runs at 5Hz. (initial value of Pr.
15)
4.
Turn the start switch (STF or STR) OFF.
REMARKS
When you want to change the running frequency, change Pr. 15 Jog frequency. (initial value "5Hz")
When you want to change the acceleration/deceleration time, change Pr. 16 Jog acceleration/deceleration time. (initial value "0.5s")
The acceleration time and deceleration time cannot be set separately for Jog operation.
Frequency setting by external terminals
Initial
Setting Range
Value
5Hz
0 to 400Hz
Frequency for Jog operation.
Acceleration/deceleration time for Jog operation. As the acceleration/
deceleration time, set the time taken to reach the frequency (initial
0 to 3600/ 360s ∗
0.5s
value is 60Hz) set in Pr. 20 Acceleration/deceleration reference frequency.
Acceleration/deceleration time can not be set separately.
Reverse
Time
rotation
ON
ON
to change to the
ON
Forward
rotation
ON
Forward
rotation
OFF
Description
Three-phase AC
power supply
Forward rotation
start
Reverse rotation
start
JOG signal
Connection diagram
for external Jog operation
JOG
Reverse
Rotates while ON
rotation
Reverse
rotation
Inverter
R/L
U
1
Motor
S/L
V
2
T/L
W
3
STF
STR
RH (JOG)*
SD
10
2
5
* When assigning the jog signal to
the terminal RH
Display
Stop
103
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents