Parameter
Example
When reading the C3 (Pr. 902) and C6 (Pr. 904) settings from the inverter of station No. 0.
Tab. 6-79: Example for data transmission
To read/write C3 (Pr. 902) and C6 (Pr. 904) after inverter reset or parameter clear, execute from step
again.
● List of calibration parameters
Pr.
Name
Terminal 2 frequency setting bias
C2
(902)
frequency
C3
(902) Terminal 2 frequency setting bias
Terminal 2 frequency setting gain
125
(903)
frequency
C4
(903) Terminal 2 frequency setting gain
Tab. 6-80: Calibration parameters
FR-E700 SC EC/ENE
Computer Send Data
Inverter Send Data
ENQ 00 FF 0 01 82
ENQ 00 EC 0 01 7E
ENQ 00 5E 0 0F
STX 00 0000 ETX 25
ENQ 00 60 0 FB
STX 00 0000 ETX 25
Communication operation and setting
Description
Set "H01" to the extended link parameter.
ACK 00
Set "H01" to second parameter changing.
ACK 00
C3 (Pr. 902) is read. 0% is read.
C6 (Pr. 904) is read. 0% is read.
Instruction
Code
Pr.
Name
Terminal 4 frequency setting bias
C5
5E
DE
1
(905)
frequency
C6
5E
DE
1
(904) Terminal 4 frequency setting bias
Terminal 4 frequency setting gain
126
5F
DF
1
(905)
frequency
C7
5F
DF
1
(905) Terminal 4 frequency setting gain
Instruction
Code
60
E0
1
60
E0
1
61
E1
1
61
E1
1
6 - 259