Parameter
NOTES
By setting "0" in Pr. 52, the monitoring of output speed to alarm display can be selected in
sequence by the SET key.
When the operation panel is used, the displayed units are Hz and A only and the others are not
displayed.
The monitor set in Pr. 52 is displayed in the third monitor position. However, change the output
current monitor for the motor load factor.
The monitor displayed at powering on is the first monitor. Display the monitor to be displayed on
the first monitor and press the SET key for 1 s. (To return to the output frequency monitor, hold
down the SET key for 1 s after displaying the output frequency monitor.)
Power on monitor (first monitor)
Output frequency
Fig. 6-68: Displaying various types of monitor
Example
When Pr. 52 is set to "20" (cumulative energizing time), the monitor is displayed on the operation
panel as described below.
Power on monitor (first monitor) Second monitor
Output frequency
Fig. 6-69: Selection of the third monitor
FR-E700 SC EC/ENE
Second monitor
Third monitor
Output current
Output voltage
Third monitor
Cumulative energizing time
Output current
Monitor display and monitor output signals
Alarm monitor
With
fault
Alarm monitor
With
fault
I001800E
I001801C
6 - 143